39
Display
Description
Comments
***
ERROR
*** 1(1)
Flowtempsen system 2
Type:
(See explananation)
Error must be fixed!
►
↓
Error
in
the
secondary
heating
system's
flow
line
temperature
sensor,
which
ensures
that
the
correct
temperature
is
sent
to
the
other
heating
system.
This
type
of
error
can
be
either
a
short
circuit
or
a
failure
in
the
sensor
or
cable.
Only
displayed
if
the
extra
heating
system
accessory
is
installed
***
ERROR
*** 1(1)
Flowtmp sensor HP
Type:
(See explananation)
Error must be fixed!
►
↓
Error
in
the
heat
pump's
flow
line
temperature
sensor
located
on
a
pipe
in
the
heat
pump
module
‐
see
the
overview
diagram
at
the
beginning
of
the
manual.
This
type
of
error
can
be
either
a
short
circuit
or
a
failure
in
the
sensor
or
cable.
***
ERROR
*** 1(1)
Hot gas sensor
Type:
(See explananation)
Error must be fixed!
►
↓
Error
in
the
heat
pump's
hot
gas
sensor
located
on
a
pipe
in
the
heat
pump
module
‐
see
overview
diagram
at
the
beginning
of
this
manual.
This
type
of
error
can
be
either
a
short
circuit
or
a
failure
in
the
sensor
or
cable.
Only
displayed
if
heat
pump
module
is
installed
***
ERROR
*** 1(1)
Outdoor sensor
Type:
(See explananation)
Error must be fixed!
►
↓
Error
in
the
outdoor
sensor
used
to
calculate
the
heating
curve.
In
the
event
of
an
error
in
the
outdoor
sensor,
Exotic
Compact
sets
the
default
value
on
the
outdoor
sensor
to
‐
5
°
C
so
that
the
heating
curve
does
not
"bolt".
This
type
of
error
can
be
either
a
short
circuit
or
a
failure
in
the
sensor
or
cable.
***
ERROR
*** 1(1)
Returnsen heat pump
Type:
(See explananation)
Error must be fixed!
►
↓
Error
in
the
heat
pump's
return
sensor
located
on
a
pipe
in
the
heat
pump
module
‐
see
the
overview
diagram
at
the
beginning
of
this
manual.
This
type
of
error
can
be
either
a
short
circuit
or
a
failure
in
the
sensor
or
cable.
Only
displayed
if
heat
pump
module
is
installed
***
ERROR
*** 1(1)
Room sensor 1
Type:
(See explananation)
Error must be fixed!
►
↓
Error
in
the
room
sensor
used
to
adjust
the
heating
curve,
among
other
things.
In
the
event
of
an
error
in
the
room
sensor,
Exotic
Compact
shuts
off
the
ability
of
the
room
sensor
to
affect
the
heating
curve.
This
type
of
error
can
be
either
a
short
circuit
or
a
failure
in
the
sensor
or
cable.
Only
displayed
if
room
sensors
are
installed
and
used
to
compensate
the
heating
curve.
***
ERROR
*** 1(1)
Room sensor 2
Type:
(See explananation)
Error must be fixed!
►
↓
Error
in
the
room
sensor
for
the
secondary
heating
system
that
is
used
to
adjust
the
heating
curve,
among
other
things.
In
the
event
of
an
error
in
the
room
sensor,
Exotic
Compact
shuts
off
the
ability
of
the
room
sensor
to
affect
the
heating
curve.
This
type
of
error
can
be
either
a
short
circuit
or
a
failure
in
the
sensor
or
cable.
Only
displayed
if
the
extra
heating
system
accessory
is
installed
and
room
sensors
are
used
to
compensate
the
heating
curve.
***
ERROR
*** 1(1)
Sun sensor
Type:
(See explananation)
Error must be fixed!
►
↓
Error
in
the
sensor
located
in
your
solar
panel
system
and
used
to
control
when
energy
should
be
sent
from
the
panels
to
the
Exotic
Compact.
This
type
of
error
can
be
either
a
short
circuit
or
a
failure
in
the
sensor
or
cable.
Only
displayed
if
the
solar
panel
control
accessory
is
installed
***
ERROR
*** 1(1)
Tank sensor lower
Type:
(See explananation)
Error must be fixed!
►
Error
in
the
sensor
in
the
lower
section
of
the
tank.
This
type
of
error
can
be
either
a
short
circuit
or
a
failure
in
the
sensor
or
cable.