GB
14
The unit features a continuous drainage port. Using a
plastic pipe (with an inner diameter of 10mm) inserts
into drain hole (on intermediate plate), reach out from
side of water tank, install it in place, and arrange the
drain pipe.
The water in the drainage tank can be continuously
drained out from the continuous port on the unit.
Cleaning and maintenance
– Wipe it with a soft damp cloth.
To Clean the Air Filter
– Open the inlet grill firstly and wash it with water
– Attach the air filter
– Insert the filter into the grill smoothly
Storing the Dehumidifier
When the unit is not being used for a long period of
time and you want to store it note the following steps:
– Empty any water left in the drainage tank.
– Fold up the power supply cord and put it in the
water tank.
– Clean the air filter
– Discard in a cool and dry place.
Troubleshooting
If something doesn’t work…
Malfunctions are often caused by minor faults. You
can easily remedy most of these yourself. Check
against the following table first before contacting Ser-
vice. You will save yourself a lot of trouble and possi-
bly money too.
If you cannot eliminate the error/fault yourself, please
contact service directly. Please be aware that any
improper repairs will also invalidate the warranty and
additional costs may be incurred.
Disposal
Disposal of the appliance
A crossed-out wheelie bin icon means: Bat-
teries and rechargeable batteries, electrical
or electronic devices must not be disposed of
with household waste. They may contain
substances that are harmful to the environ-
ment and human health.
Consumers must dispose of waste electrical devices,
spent portable batteries and rechargeable batteries
separately from household waste at an official collec-
tion point to ensure that these items are processed
correctly. Information on returning these items is
available from the seller. Sellers are required to
accept these items free of charge.
Batteries and rechargeable batteries, which
are not permanently installed in waste elec-
trical devices, must be removed prior to dis-
posal and must be disposed of separately.
Lithium batteries and battery packs in all systems
must only be retuned to a collection point when dis-
charged. Batteries must always be protected against
short circuits by covering the poles with adhesive
tape.
All end users are responsible for deleting any per-
sonal data stored on waste devices prior to their dis-
posal.
Disposal of the packaging
The packaging consists of cardboard and
correspondingly marked plastics that can
be recycled.
– Make these materials available for
recycling.
Technical data
*)
The specified values are emission values and do not necessarily
represent safe workplace values. Although there is a correlation
between emission and immission levels, this cannot be used to
infer whether additional safety measures are necessary or not.
Factors which affect the current immission levels at the work-
place, include the type of room, other sources of noise, e. g. the
number of machines operating and other processes taking place
DANGER! Risk of injury!
Always pull the
mains plug out before commencing any
work on the device.
DANGER! Risk of injury!
Improper repairs
can result in the product functioning
unsafely. This endangers yourself and your
environment.
Fault/malfunction
Cause
Remedy
Product does not run
No mains voltage?
Check cable, plug, socket and fuse.
Condensate tank not fully inserted? Insert the condensate tank correctly
Condensate tank full?
Empty and replace the condensate
tank
Output too low
Intake filter clogged?
Clean the intake filter
Air circulation is impeded?
Increase the distances to walls, fur-
niture etc.
Operation is noisy
Is the unit tilted or unsteady?
Move the unit to a stable, sturdy lo-
cation.
Item number
107597
Rated voltage
230 V~, 50 Hz
Nominal output
280 W
Air output
150 m³/d
Sound pressure level
(L
PA
)
42 dB(A)
Condensate tank vol-
ume
2 l
Dimensions
27,6 × 18,5 × 48 cm
Coolant
R290, 45 g
Summary of Contents for LEF-200-40
Page 1: ...LEF 200 40 107597 DE Luftentfeuchter GB Dehumidifier PL Osuszacz powietrza...
Page 2: ...2 bersicht Overview Przegl d Inbetriebnahme Commissioning Uruchomienie 1 2...
Page 3: ...3 1...
Page 4: ...4 Bedienung Operation Obs uga 1 2 3 4...
Page 5: ...5 Wartung Maintenance Konserwacja 5 1 2...
Page 22: ...22...
Page 23: ...23...