background image

WARNING

•  Always be sure that your respirator is:  a) suitable for all expected respiratory hazards in the workplace; b) fitted properly – refer to 

manufacturers instructions;  c) filter is replaced when necessary. 

•  Do not use for respiratory protection against unknown airborne contaminants, when concentrations of contaminants are unknown or 

exceed 10x workplace exposure limits, against substances immediately dangerous to life or health.  

 

 

 

•  Do not modify or alter filters or face-pieces. 
•  Use with Euromarc 710 series respiratory. 
•  If in doubt about the correct use or suitability of this device for any application, consult your supervisor, occupational health 

professional or contact Euromarc.

•  Always check the filters have not exceeded the use-by date. 
•  Do not use where there may be a deficiency of Oxygen.

718 & 719 FILTER INSTRUCTIONS FOR USE

1.  Check identification on the filters to ensure you have the correct filters for the application.
2.  a) Align the filter bayonet fitting with the facepiece bayonet fitting. b) Rotate 1/4 turn clockwise to attach (fig 9, 10). 

CAUTION: 

Over rotation will result in damage to the filter and facepiece.

Note:

 These filters are supplied in pairs of identical classes and type and must be fitted, used and replaced at the same time.

3.  Leave work area immediately, check integrity of respirator, and replace any parts if: a) damage has occurred or is apparent b) 

dizziness, illness or irritation occurs c) breathing resistance increase. Dispose of all used filters.

STORAGE

Store in original packaging before use. Store between -10 and +35°C and less than 70% humidity. End of Shelf Life is 5 years after date of 
manufacture.

APPROVALS

These filters comply with Australian/New Zealand Standard AS/NZS 1716:2012 and have been accredited and certified  
as such by SAI Global.

GAS/VAPOUR

FILTER ABEK

Combination filter, for use against 

Organic (boiling point >65°C), 

Inorganic vapours, and Acid gases, 

Ammonia and its derivatives.

C719

2

Euromarc 710 Series Respirator

When working with a variety of 

solvents and acid gases such as 

chlorine, hydrogen chloride,  

sulfur dioxide, hydrogen fluoride, 

hydrogen sulphide. Acid cleaning, 

de-greasing, paints, thinners and 

glues. Ammonia, refrigeration.

719

GAS/VAPOUR 
FILTER ABEK

719

AS/NZ 1716 : 2012 Lic 40344

SAI Global