Sensors
EUROMAG | SENSORS | Ed. 04/2019
3.6
INSTRUCTIONS FOR DIAMETER REDUCTION
In the case of diameter reduction, please refer to the indications shown in the figure below.
1
2
3
5
REFERENCES
1
Vent
2
Recommended maximum vertex angle: 15°
3
Flow rate meter
4
Flow
5
Discharge
Flowmeter type
U
D
Full Bore
5
3
Reduced Bore
0
0
Insertion
15 10
U * DN
15°
D
D
15°
DN
4
D * DN
Fig. 43 Installation on pipes with diameter reduction
The diameter reduction introduces a pressure drop in the system. Pay attention, especially when
the flow rates are high and if the section reduction is applied simultaneously with the use of
reduced section meters.
In the case of low pressures, the section reduction could also lead to cavitation formation,
especially if the meter has a reduced section; this condition must be absolutely avoided.