fig_335_15
fig_336_2
fig_336_3
fig_336_1
20
EUROMAG | MC608 | TD210-1
www.euromag.com
UNDERGROUND INSTALLATIONS
• The remote sensor is protected to IP68/NEMA
6P and can be positioned underground. We
recommend the use of gravel for at least
300mm (12 inches) around the sensor. This
provides certain drainage and prevents dirt from
solidifying on the sensor, in addition it facilitates
its location whenever new excavations are
required. Before covering the gravel with earth,
we suggest using electrical cable identification
tape above the gravel itself. The remote sensor
cable should pass through a conduit made of
plastic and of minimum 50mm (2 inches).
• It is recommended the junction box made of
steel in the case of underground installations.
3.3.6 IMPORTANT GENERIC INDICATIONS
FOR A CORRECT INSTALLATION
• Install a suitable anti-vibrational protection if
any vibration arise.
• DO NOT expose the flow meter to vibrations and/
or movement, which may affect its performance
and duration.
• AVOID exposing the flow meter to strong or
nearby magnetic fields.
Protective cover
Fill with an
adequate amount
of material
AVOID ANY
EXCESSIVE
VIBRATIONS