LAMPO Multifunction Unit
4.8.3.3 PUMP PRIMING - E-SELF
3
1
5
2
4
POSITION
DESCRIPTION
1
Delivery valve
2
Filling cock
3
E-Self
4
E-Self Suction
5
Start / Stop
6
Vent
DESCRIPTION
CIM-136
CEM-120
DESCRIPTION
CIM-136
CEM-120
1.
Make sure of machine stability and its
ground connection, turn the control
unit on using the “Control Unit OFF-ON”
selector
(for version with CEM 120 only).
CONTROL UNIT
OFF ON
2.
Press “Function” key to select the manual
operation mode
OFF
AUT
MAN
PROG
3.
Press “Start” button to start the engine
START
4.
Press “Pump protection disabling/
enabling” button to disable control unit
intervention for anomalies on working
pressure.
5.
Enable the auxiliary circuits from the
LAMPO command and control unit (Fig. 5.12)
(for version with CEM 120 only).
AUX
OFF ON
6.
Connect the E-Self pump plug to the single-
phase service socket (pos.
10
fig.
4.7.4
)
10
7.
Activate the protection of the socket by
lifting the switch
Q3
(see
4.7.5
)
Q3
8.
Remove the connection of the suction pipe
(
4
) and fill the E-Self pump with water
9.
Close the pump delivery valve (
1
)
10. Open the filling cock (
2
)
1
2
4
11.
Connect the suction pipe (
4
) and immerse
it in water
12.
Start the E-Self pump (
5
) until water
comes out from the delivery line
13.
Stop the E-Self pump (
5
), close the filling
cock (
2
)
5
2
4
14.
Before starting the pump, check that the
potentiometer is at minimum.
(for version with CEM 120 only).
MIN MAX
32