LAMPO Multifunction Unit
4.8.3.1 E-PLUTO PUMP PRIMING
1
2
3
4
POSITION
DESCRIPTION
1
Pluto lever
2
Pluto connection valve
3
Delivery valve
4
Pluto exhaust
DESCRIPTION
CIM-136
CEM-120
DESCRIPTION
CIM-136
CEM-120
1.
Make sure of machine stability and its
ground connection, turn the control
unit on using the “Control Unit OFF-ON”
selector
(for version with CEM 120 only).
CONTROL UNIT
OFF ON
2.
Press “Function” key to select the manual
operation mode
OFF
AUT
MAN
PROG
3.
Press “Start” button to start the engine
START
4.
Press “Pump protection disabling/
enabling” button to disable control unit
intervention for anomalies on working
pressure.
5.
Enable the auxiliary circuits from the
LAMPO command and control unit (Fig. 5.12)
(for version with CEM 120 only).
AUX
OFF ON
6.
Close the pump delivery valve (
3
) and
open PLUTO cock (
2
)
3
2
7.
Pull the lever (
1
) to activate PLUTO
priming system.
1
8.
Wait until water starts coming out of vent
(
4
) and close the cock connecting PLUTO
(
2
) to the pump.
2
9.
Reposition the silencer exhaust through
the lever (
1
)
1
10. Before starting the pump, check that the
potentiometer is at minimum.
(for version with CEM 120 only).
MIN MAX
29