Page 33
7.3 Spark plug
Recommended spark plugs: NGK CR5HSB / DENSO U16FSR-UB
8. Transport and storage
PROCEDURE
-
Remove the cover at the top of the generator.
-
Remove the sparking plug cover.
-
Remove dirt around the sparking plug.
-
Use a sparking plug wrench to unfasten the sparking plug.
-
Check the sparking plug, replace if the isolation has cracked.
-
Clean the sparking plug with a steel brush if you want to reuse it.
-
Measure the electrode distance, be careful not to damage the sparking plug.
-
The distance should be 0,6 mm – 0,7 mm.
-
Insert the sparking plug carefully and fasten it with a sparking plug wrench.
-
Normally you have to fasten a new sparking plug by
½
turn by the means of the sparking plug wrench.
-
You only have to fasten a used sparking plug by
1/8
–
¼
turn.
-
Mount the sparking plug cover .
-
Put the cover back on the generator.
NOTE
By transport the generator must be placed in normal standing position and the upper part of the gasoline cover
is turned anti-clockwise to the ”OFF” position.
WARNING
-
Never overfill the fuel tank.
-
Never use the generator while it is onboard a vehicle, only operate the generator in an open and
ventilated area.
-
By transport you must avoid direct sun light. If the generator is exposed for direct sun light for many
hours, gasoline steams may evaporate and self-ignite.
-
By transport on uneven roads for longer periods of time you should drain all gasoline.
-
Always draw attention to the storage area being free for dust and damps.
-
Drain all fuel from the generator before storage.
Cover
Handle
Wrench
Cap