00062596.DOC, Version 1.0
19/19
Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of
same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1:
Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2:
Remove the old fuse from the fuseholder.
Step 3:
Install the new fuse in the fuseholder.
Step 4:
Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
230 V AC, 50 Hz ~
Power consumption:
620 W/640 VA
Maximum ambient temperature T
a
:
45° C
Maximum housing temperature T
C
:
150° C
Min. distance from flammable surfaces:
0.5 m
Min. distance to lighted object:
2 m
Fuse:
T 4 A, 250 V
Dimensions:
275 x 325 x 295 mm
Weight:
6 kg
Accessories:
No.:
PHILIPS MSR 575/2 95V/575W GX-9,5 1000h
89107015
GE CSR575/2 SE 95V/575W GX-9,5 1000h
89107000
OMNILUX OSD 95V/575W GX-9,5 2000h 6000K
89107005
OMNILUX OSR 575/2 95V/575W GX-9,5 1000h
89107017
SYLVANIA BA575/2SE NHR 575W GX-9,5 8500K
89107020
OMNILUX OSD 95V/575W GX-9,5 1000h 7200K
89107205
OSRAM HSR 575/72 95V/575W GX-9,5 1000h
89107210
Barn doors ML Multi Spot black
41600180
Barn doors ML Multi Spot silver
41600184
Saveking Safety bond 3x600 silver
58010250
Saveking Safety bond 3x600 black
58010252
Please note: Every information is subject to change without prior notice. 24.08.2011 ©