Turn on the device. The display indicates the last operating mode. The operating modes can be selected by
means of the display and the control buttons. All settings remain stored even if the device is disconnected
from the mains. The device can be operated in stand-alone mode via the control board or in DMX-controlled
mode via any commercial DMX controller and via QuickDMX with the optionally available EUROLITE
QuickDMX USB Wireless Transmitter/Receiver.
The device is additionally equipped with two rotary dials. The use of these rotary dials is possible as long as
there is no DMX signal at the DMX input.
Menu structure
Press the
MENU
button so many times until the desired function is indicated on the display. Use the
ENTER
button to select the function. With the buttons
UP
and
DOWN
you can select the mode or change values.
Confirm with
ENTER
.
Mode
Display
Function
DMX mode
Addr
6CH
d001-507
6-channel mode and start address
4CH
d001-509
4-channel mode and start address
2CH
d001-511
2-channel mode and start address
White color presets
Stat
S 01 – S 03
Constant lighting in one of 3 preset
colors
Automatic mode
Auto
Au01 – Au03
Automatic programs
Sound control
Soun
So01 – So03
Sound-controlled programs
Running speed in
automatic and sound-
controlled mode
SPEE
SP1 – SP9
Program running speed slow > fast
Microphone sensitivity
for sound control
SEnS
SE1 – SE9
Microphone sensitivity
low > high
White color setting
Colo
U000 - U255
Warm white 0-100%
C000 - C255
Cold white 0-100%
Color temperature
Temp
2800K-6500K
Color temperature setting
*
Dimmer
diMM
dI1 - dI9
Total brightness (Stat, Auto, Soun and
Colo modes) dark > bright
Strobe
FLAS
0 - 9
Strobe effect slow > fast
Sound control
„silent scene“
SILE
on
LEDs off if there is no music signal
oFF
LEDs remain on if there is no music signal
Behaviour in case of
missing DMX signal
LoSt
bLac
LEDs go off
HoLd
Spot holds the last received signal
FuLL
All LEDs 100% on
Stat
Pre-selected static color 01-03
Auto
Pre-selected auto program 01-03
Slave mode
SLAV
SLAU
Slave mode
Energy saving mode
batt
SuPE
Extra bright operating mode
norM
Normal operating mode
Econ
Energy saving mode
Potentiometer
PotE
on
Function for rotary dials activated
oFF
Function for rotary dials deactivated
PWM frequency setting
rEFr
0.9, 1.5, 2.5, 4, 5, 6, 10,
15, 20, 25kHz
PWM frequency
(pulse-width modulation)
Firmware version
Vx.x
Vx.x
Current software version
*
=
See Color temperature settings in 6-Channel-mode CH 6