The Plexus Air Control
Your insert will has three levers on the front facia of the insert hidden behind the lower door when closed.
The air direction lever, the air volume lever and the minimum bypass lever.
1
2
3
+
-
Air Direction Lever
Air Volume Lever
Minimum bypass lever
This lever should be set to maximum at all
times unless advised otherwise by your
heating engineer or the Euroheat Technical
Department. This control governs the amount
of air entering the insert when the air volume
lever is closed.
Air Direction Lever
When the direction lever is in its uppermost position the air enters the insert above the fire, and when set to its
lower position air enters the insert from beneath the grate. Positioning the lever at its mid position will supply
air both over and under the fire and this position is used when lighting a fire or burning manufactured smokeless
coals. It should be set to its bottom position when burning natural smokeless coal such as anthracite and at its
top position when burning wood.
1
2
3
1
2
3
1
2
3
Lighting And Manufactured
Smokeless Coals
Anthracite
Wood
1
2
3
1
2
3
This Lever May Be Hot.
Always Use The Insert Tool To Make Air
Direction Adjustments.