© EUROHEAT DISTRIBUTORS (H.B.S) LTD. July 2011
Instructions Part Number IN1231 Ed 1
11
3.2 Requirement for the Baseplate of a Tiled Hearth
Installation surfaces made from flammable materials such as parquet floors, PVC floors, etc. must always be
protected by mounting the stove on a fireproof plinth which extends beyond the boiler at the sides and front.
The plinth must be designed to be load bearing and fireproof.
The following minimum dimensions should be observed when positioning the stove on the plinth or tiled
floor:
At least 30 cm on each side of the plinth and at least 50 cm from the front of the plinth. The reference points
are not the outer edge of the boiler, but the firebox opening (see drawing).
3.3 Connections Positioned at Rear of Boiler
Please see page 6 for the markings for the individual connections. This includes the exact dimensions for the
connections on the rear side.
The overall width of the boiler is 584 mm.
50cm
30cm