© EUROHEAT DISTRIBUTORS (H.B.S) LTD. July 2011
Instructions Part Number IN1231 Ed 1
10
EVO installed in a living room
Distance A:
At least 80 cm in the radiation zone must be considered as an area where people and objects are not allowed
when the stove is operating.
Distance B:
A minimum distance of 40 cm should be maintained from movable objects such as chairs or tables.
Distance C:
At least 10 cm between the flue tube and the wall if it is not inserted directly in the rear wall.
Distance D:
At least 50 cm from immovable objects on the right and left sides to allow for servicing and maintenance.
Distance E:
Minimum distance between boiler and rear wall in the installation room providing that distance C is observed,
or the flue tube is inserted directly in the rear wall.
E = 20 cm distance from rear wall if the boiler is installed without automatic conveying system.
E = 20 cm distance if installed with the automatic conveying system, visionconvey AIR, if the hoses are passed
straight down into the floor or are routed to the side in the same room.
E = 35 cm distance if installed with the automatic conveying system, visionconvey AIR, if the hoses are routed
in the rear wall behind the boiler.
3 Sighting of the Stove
3.1 Minimum Distances from Flammable Materials
These distances are our recommended minimum distances but the fire safety requirements of applicable
standards must be observed when constructing the system as a whole.
All flammable materials in the immediate vicinity of the boiler must be protected from the effects of heat.
C
D
A
B
E