18
EN
19
EN
Maintenance procedures approximately once a year
•
Unplug and unload the appliance.
•
Remove any particles that could block the drain pipe located inside the cabinet,
on the ledge at the bottom.
•
Clean the inside of the compartments with water and a gentle cleaning product.
•
Rinse thoroughly. Dry with the EuroCave microfibre cloth provided.
•
Glass sections must be polished with the EuroCave non-abrasive microfibre cloth
provided, after first cleaning with a glass cleaning product.
•
Replace the active charcoal filter housed in its hatch under the control panel (see
chapter 6,
IV). Remove the charcoal filter manually. It is available from your usual
retailer. It must be replaced by a manufacturer’s part.
•
Check that the door seal is in good condition. It is often necessary to clean the seal.
Cleaning with unsuitable products can cause premature wear of the seal. You should
therefore observe certain rules: Whenever the seal is cleaned, it must be rinsed
with clean water. no traces of cleaning product must be left on the seal. EuroCave
recommends that you only use a mild soapy solution. If cleaning with this type of
solution proves insufficient, it is possible to occasionally use an an ethanol-based
solution, but with a concentration of less than 10 %, and taking care to rinse the
seal with clean water.
•
To remove words written with the white marker pen on our bottle identification
labels, use a damp cloth.
•
Use a damp cloth to clean the fronts of the shelves.
•
Use the EuroCave microfibre cloth to clean glass or plastic sections of your
cabinet.
•
Clean the humidity control tray every 1 - 2 years depending on the quality of the
water used. Take the tray out of its slot. Unscrew the upper panel and clean the
different elements with soapy water. Rinse thoroughly, screw the upper panel
back on and fill the tray (see chapter 4). Put the tray back into the slot provided
in the cabinet.
•
Clean the two metal strips used as an electrical contact for lighting the shelves
with a damp cloth.
•
If dust has settled on the ventilation openings on the back of the wine cabinet,
simply remove it with a vacuum cleaner.
Your EuroCave wine cabinet is a tried and tested appliance.
Never use a cleaning product containing acetone, petrol or alcohol, white spirit or synthetic thinner, which could damage the front.
Possible incidents
Causes
Corrective action
The pictogram
is displayed and the alarm
is ringing. The
button is red.
(Temperature alarm)
The temperature
has been 4°C higher
or lower than the
selected temperature
for at least 24hrs.
Check that the door is closed.
Check the condition of the door seal.
If you have loaded your cabinet with a large amount of bottles in the
past few hours, wait a while then check again.
If the alarm continues, contact your EuroCave retailer.
The
pictogram is still displayed even
though the previous corrective action has been
taken. The
button is red.
(Temperature alarm)
Operating fault
Unplug the cabinet and contact your EuroCave retailer.
The
pictogram is displayed. The
button is red.
(Low humidity level alarm)
The humidity level has
been below 50% for
96hrs.
Fill the humidity control tray (see chapter 4).
If the alarm continues, contact your EuroCave retailer.
The
pictogram is displayed, the
button is red and the alarm is ringing.
(Low humidity level alarm)
The humidity level has
been below 50% for
60 days.
Fill the humidity control tray (see chapter 4).
If the alarm continues, contact your EuroCave retailer.
The
pictogram is flashing. The
button
is red.
(High humidity level alarm)
The humidity level has
been above 90% for
72hrs.
Unplug your appliance then plug it back in again.
If the problem continues, contact your EuroCave retailer/customer
services.
The
pictogram is flashing the
button
is red and the alarm is ringing.
(High humidity level alarm)
The humidity level has
been higher than 90%
for a week.
Unplug your appliance then plug it back in again.
If the problem continues, contact your EuroCave retailer/customer
services.
The
pictogram and Er1 are displayed and
the alarm is ringing.
The
button is red.
(Temperature sensor fault alarm)
Temperature sensor
fault alarm
Unplug your appliance then plug it back in again.
If the problem continues, contact your EuroCave retailer/customer
services.
7/ EVERYDAY MAINTENANCE
8/ OPERATING FAULTS
VII. Disabling the audible warning signal of the alarms
When your appliance has a fault, an audible warning may accompany the visual warning. To turn off this alarm this audible warning, simply briefly press the
key.
Disabling the audible warning signal of the alarms does not
disable the visual warnings.
The following alarms have an audible warning signal that can be disabled:
•
Temperature alarm
•
Low humidity level alarm
(after being below 50% for 60 days)
•
High humidity level alarm
(after being above 90% for one week)
•
Temperature sensor fault alarm
+ « Er1 »
•
“Erh” humidity sensor fault alarm
•
Open door alarm
(after 15 minutes)
VIII. Placing the screen on standby
To place the screen on standby, briefly press the
key. Repeat the process to exit standby mode.
The cabinet remains in operation when the screen is in standby mode.
•
Temperature alarm
•
Low humidity level alarm
•
High humidity level alarm
•
Temperature sensor fault alarm
+ « Er1 »
•
“Erh” humidity sensor fault alarm
•
Open door alarm
It is not possible to activate standb
y mode whilst
the following warning lights ar
e on:
+
set
3
Remove the existing charcoal filter.
4
Insert the EuroCave charcoal filter (with the EuroCave label facing
you), taking care to first remove the protective plastic.
5
Push the hatchupwards and screw the button back on.
N.B.: Only use genuine EuroCave parts.
6/ USING YOUR WINE CABINET FOR THE FIRST TIME