GAS CONNECTION
This appliance shall be installed only by authorised personnel and in accordance with the manufacturer’s installation
instructions, local gas fi tting regulations, municipal codes, electrical wiring regulations, AS 5601 - Gas Installations
and any other statutory regulations.
The appliance is adjusted to work at gas indicated on the label which is applied on the glass-window of the oven
door and on the cooker packing.
Installation for Natural gas
Connected regulator (B) to fi tting (A) which is then fi tted to elbow (F). Ensure arrow on regulator point in the
direction shown. Fitting (D) to be supplied by installer (fi g. 20). Adjust regulator to give test-point pressure given
on data label and on page 25, with one large or one medium burner alight at maximum.
Position of Regulator
If stove is to be installed on legs, a gas pipe between fi tting (A) and (B) (fi g. 20) will allow location of the regulator
(B) underneath the stove for adjustment and maintenance. If stove is installed on it’s base, the regulator should
be fi tted at rear of stove on fi tting (E) (fi g. 20) for maintenance and adjustment.
Note: When the regulator is fi tted at the rear of the cooker at least 60 mm clearance is required.
Installation to L. P. Gas
Connect by using a copper pipe starting, from the threaded fi tting of elbow (F) (fi g. 21).
When converting from Natural Gas to Propane ensure that the NG regulator is removed and replaced with the Test
Point Assembly. A gas regulator suitable for a supply pressure of 2.75 kPa should be part of the gas tank supply.
Installation using fl exible connection
As an option, the cooker may be installed with a fl exible connection hose, which complies with AS/NZS 1869 (AGA
Approved), 10 mm ID, class B or D, Minimum 1000 mm - Maximum 1200 mm, as an alternative connection.
• All cookers offer left or right hand connection. The manifold has a fl at fl air over which is inserted a screw nut
male ½” gas.
• An isolating tap and pressure regulator must be fi xed to the rear wall and the fl exible pipe attached by means
of a union connector.
• The gas connection and isolating tap must be accessible to a service person or inspector.
• The hose assembly must be installed in accordance with AS5601 for a high level connection. The hose should
not be subjected to abrasion, kinking or permanent deformation and should be able to be inspected along its
entire length. Unions compatible with the hose fi ttings must be used and connections tested for gas leaks.
The fi xed consumer piping outlet should be at approximately the same height as the cooker connection point,
pointing downwards.
• The hose should be clear of the fl oor when the cooker is in the installed position. The anti-tilting chain supplied
should be anchored to the lower hook fi xed to the wall so that the chain prevents strain on the hose connections
when the cooker is pulled forward.
INSTRUCTIONS FOR THE INSTALLER
F
E
C
A
B
D
20
A
C
F
C
E
T
21