Milano Installation
I
Euro Fireplaces recommends the use of a designated 125mm Milano
Flue, however a 125mm to 6” adapter can be used in conjunction with a
Euro Fireplace heat shield, in that case a standard 6” flue may be used.
If a second perforated flue is used instead of the heat shield, clearance
would be 425mm from the back of the flue instead of 225mm from the
back of the heat shield.
I
Make sure a minimum of 4m of flue from the heater to the cowl is used.
I
A straight flue line is always the preferred option however 45 deg
bends may be used if necessary.
I
The original paint on the flue is Stove Bright Charcoal, or Stove Bright
Satin Black or Matte Black. You may need this paint for any touch ups.
I
Through the wall kits are only recommended after the first flue length
straight up, and then out the wall with a 45 degree wall penetration.
Triple flue should be used on the outside to ensure the flue stays warm
all the way up for better draw.
CLEARANCE
Milano Flue Kit 225mm from back of the Heat shield, 540mm side, 475mm
corner.
HEARTH
300mm in front, 200mm side
I
Euro Fireplaces recommends 400mm in front. The hearth may be
tile underlay and ceramic or stone tiles, or a Euro Fireplace 8mm
toughened glass, which is tested and approved to
I
Australian standards. When using a glass hearth Euro Fireplaces
recommends the use of a Milano Tray in front of the heater for extra
protection. The Tray is available from your local distributor.
36 - INSTALLATION INSTRUCTIONS