background image

5.

Install housing. 

Conduct cables through the top hole of the
housing, and then turn the housing thread pipe
head into suspender and fasten the connection
with two M5 screws

NOTE: Apply water-proof tape to the thread in
the case of outdoor dome. If installation height is
not high enough, mount housing directly into the
base.

6.

Connect cables. 

Plug cables into corresponding sockets on circuit
board. Reinstall the circuit board and turn on the
power. The red LED is on if connections are
correct. Turn off the power after checking. 

NOTE: Names of the interfaces are marked on
terminal block or PCB. Connect cables as
picture shows. Make sure power is off before
connecting.

7.

Set dome ID, baud rate and protocol. 

Set dome ID, bard rate and protocol by
configuring DIP switches (see APPENDIX I). 

Remove the packing sponge.

SW 1

SW 2

8.

Down cover preliminary installation. 

Attach the safety chain with a M3 nut as picture
shows. 

NOTE: Connect plug into the socket on heater in
the case of outdoor dome

EVC-TP-SO453ARW, EVC-TP-SO448AN

   

                 

      

www.eurovideo-cctv.com

- 17

-

- 17

-

Summary of Contents for EVC-TP-SO448AN

Page 1: ...tdoor Use Note Read this manual carefully before installation and operation Keep it handy for later reference This manual covers installation and operation of 3 type of speed dome embedded indoor and outdoor EVC TP SO453ARW EVC TP SO448AN www eurovideo cctv com INSTRUCTION MANUAL ...

Page 2: ...m 26 Joystick AF AI 26 AF Resume Time 26 AI Resume Time 27 Iris ALC 27 Iris PLC 27 Day Night 27 CAMERA PARAMETERS 32 Frame Limit 28 Shutter 28 Exposure 28 Preset Freeze 28 White Balance 29 BLC Mode 29 PAN TILT PARAMETERS 30 Auto Stop Time 30 Speed Amplify 30 Proportional P T 30 Set North 30 AUTO RUNNING 31 Preset 31 Tour 32 Pattern 33 Cruise 34 Zone 35 Park Time 36 Park Action 36 PRIVACY MASK 37 A...

Page 3: ...rity levels Alarm driven Pattern preset etc Position Resume After Alarm Variable Cruise Speed 0 1 150 sec OSD Menu for Programmable Functions Proportional Pan Tilt Speed Vertical Tilt Unobstructed 0 to 90 Auto Running Memory Against Power Outage Auto Running Resume after Manual Operation System preheat before camera power on On Screen display for compass and tilt angle System and environment tempe...

Page 4: ... 3s 3 9s 6 3s 3 9s 6 3s Angle of View 47 2 2 47 2 2 54 2 5 48 2 7 47 3 0 Sync system Internal external Min Illumination 0 9Lux 0 02Lux 0 013Lux 0 7Lux 0 01Lux S N Ratio 50db Iris Auto Manual White Balance Auto Manual Gain Auto AE Control Auto Manual BLC On Off Privacy Mask No Yes Yes No No Focusing system Auto Manual Video Output 1 0 0 2Vp p Accessories Mounting Wall mount bracket Pendant mount ac...

Page 5: ... are related to installation in advance It is recommended that the stand of dome be 8 times stronger than the weight of the dome and its accessories Keep all the original dome package materials in case of future repacking and transportation Choose and install speed dome according to environment requirement Refer to the Product Features This product conforms to IP66 standard as specified in Housing...

Page 6: ...mpedance Solid copper wire 95 braided copper shield Check the max transmission distance referring to the chart below Model Distance RG 59 U 750ft 229m RG 6 U 1 000ft 305m RG 16 U 1 5000ft 457m RS485 Cable 0 56mm 24AWG twisted pair wire DIP SWITCH SETTING See appendix I Protocol and Baud rate Dome address Video cable type Resistor jumper Alarm output method EVC TP SO453ARW EVC TP SO448AN 6 www euro...

Page 7: ...MOUNT TYPE IN CEILING MOUNT WALL MOUNT CORNER MOUNT POLE MOUNT PENDANT MOUNT EVC TP SO453ARW EVC TP SO448AN 7 www eurovideo cctv com ...

Page 8: ...he circuit board Unscrew the screw to open the circuit board on connection board Scr ew 4 Conduct cables Prepare wiring and then put Power RS485 Video cables through waterproof connector on the top of housing Turn the connector into the top hole of the housing W at er pr oof C onnect or 5 Connect cables Plug cables into corresponding sockets on circuit board When finished fix the circuit board bac...

Page 9: ...tches see APPENDIX I NOTE Remove the packing sponges SW 1 SW 2 9 Install Pan Tilt Module Push the black liner into the two tabs Install the pan tilt module with two clips match color of AMP sockets Gently push the module upward until hearing two clicks NOTE Remove the lens cover Sam e Col or AM P Socket Tab Tab 10 Install down cover Fasten the safety chain on housing Align clasps and mounting hole...

Page 10: ...ircuit board on connection board 4 Install housing Conduct cables through the hole on top of the housing Align the fast connector to bracket and fix with 2 M5 screws NOTE Apply water proof tape to the thread in the case of outdoor dome 5 Connect cables Plug cables into corresponding sockets on circuit board Reinstall the circuit board and turn on the power The red LED is on if connections are corr...

Page 11: ...dome 8 Install black liner and Pan Tilt Module Push the black liner into the two tabs Install the pan tilt module with two clips match color of AMP sockets Gently push the module upward until hearing the click NOTE Remove the lens cover Bl ack Li ner 9 Install down cover Unscrew the two M4 screw on down cover ring Push up the down cover into the housing and then fasten down cover with two M4 screw...

Page 12: ...se M8 nuts to fasten corner base on the mounting surface NOTE Put cables through the wall of aside the corner base 3 Install bracket Put cables through the cavity of bracket and fasten bracket on base 4 Release the connection circuit board Unscrew to release the circuit board on connection board 5 Install housing Conduct cables through the hole on top of the housing Align the fast connector to bra...

Page 13: ...SW 2 8 Down cover preliminary installation Attach the safety chain with a M3 screw as picture shows NOTE Connect the plug into socket on heater in the case of outdoor dome 9 Install black liner and Pan Tilt Module Push the black liner into the two tabs Install the pan tilt module with two clips match color of AMP sockets Gently push the module upward until hearing two clicks NOTE Remove the lens c...

Page 14: ...housing Conduct wirings through the hole on top of the housing Align the fast connector to bracket and fix with 2 M5 screw NOTE Apply water proof tape to the thread in the case of outdoor dome 5 Connect cables Plug cables into corresponding sockets on circuit board Reinstall the circuit board and turn on the power The red LED is on if connections are correct Turn off the power after checking NOTE ...

Page 15: ...e 8 Install black liner and Pan Tilt Module Push the black liner into the two tabs Install the pan tilt module with two clips match color of AMP sockets Gently push the module upward until hearing two clicks NOTE Remove the lens cover Bl ack Li ner 9 Install down cover Unscrew the two M4 screws on down cover ring Push up the down cover into the housing and then fasten down cover with two M4 screws...

Page 16: ...ilica gel along the top of bracket base in the case of outdoor dome 3 Install suspender Conduct wirings through the cavity of suspender and then turn the threaded pipe head into the bracket base and fasten the connection with a M5 screw NOTE Apply water proof tape to the thread and put silica gel to the suspender as picture shows in the case of outdoor doom 4 Release the circuit board Unscrew to r...

Page 17: ...oard and turn on the power The red LED is on if connections are correct Turn off the power after checking NOTE Names of the interfaces are marked on terminal block or PCB Connect cables as picture shows Make sure power is off before connecting 7 Set dome ID baud rate and protocol Set dome ID bard rate and protocol by configuring DIP switches see APPENDIX I Remove the packing sponge SW 1 SW 2 8 Dow...

Page 18: ...the module upward until hearing two clicks NOTE Remove the lens cover Bl ack Li ner 10 Install down cover Unscrew the two M4 screws on down cover ring Push up the down cover into the housing and then fasten down cover with two M4 screws NOTE Apply the lube to the O ring in the case of outdoor dome Lube Lube EVC TP SO453ARW EVC TP SO448AN www eurovideo cctv com 18 ...

Page 19: ... SYSTEM CONNECTION EVC TP SO453ARW EVC TP SO448AN www eurovideo cctv com 19 19 ...

Page 20: ... dome the boot up information will display on screen and then the dome will conduct self testing System booting up will show on the screen until boot up success shows up The whole boot up process lasts about 40 seconds This screen display disappears once the dome receives any effective command Protocol Dome control protocol Baud Rate Dome control baud rate Camera ID The dome ID address set by dip ...

Page 21: ...ct user needs to input the correct 6 bit password to enter the OSD menu Default password is 123456 To enter password move the joystick up or down to select number 0 9 move the joystick left or right to choose password digit If the input password is wrong the password input window will disappear OSD menu will close automatically after 1 minute without any operation All the settings will be saved au...

Page 22: ... the cursor to Camera move the joystick right to select it Select BLC MODE in the same way NOTE Here in after menu paths are written in the following format Main Menu Camera BLC Mode BLC Level 3 The BLC Level option blinks Move the joystick up or down to change the option move the joystick left to save the changing When finished select Back to return to upper menu EDITING TITLES Move the cursor to...

Page 23: ...ght input the serial number according to the Site S N and then turn the joystick left to exit setting Point cursor to Back and turn joystick right to exit Finally turn joystick up or down to select desired ID number When finished move the joystick left to save the settings Name is the title of the dome Assigning a name to a dome helps user to remember which dome it is Broadcast Add is used to set ...

Page 24: ...d Enter the old password Back If old password is correct cursor goes back behind Input Password so that new password can be input If old Password is not correct cursor goes back to front of Input Password Password can not be changed in this case Confirm When and only when new password is entered user can get to this menu item If password is not the same as entered the first time it remains unchang...

Page 25: ...ff Exposure Off White Balance Auto BLC Level 000 Speed Amplify Off Proportional P T On Pswd Protection Off Park Time Off Park Action Off Arm Disarm Disarm Reset Delay 004 SYSTEM REBOOT Main Menu System Info System Reboot Select System Reboot to reboot the dome Settings will not change after restarting EVC TP SO453ARW EVC TP SO448AN www eurovideo cctv com 25 25 Site Info Display Setup Initial Infor...

Page 26: ...image Focus can also be manually controlled by keyboard or matrix For manual operation details please refer to keyboard or matrix operation manual This item sets the time to restore auto focus after focus is manually changed The default setting is 005 Off Never restore auto focus after switch to manual 001 255 The dome will start auto focus that number of seconds after user manually adjust focus N...

Page 27: ...e default value is strongly recommended IRIS PLC Main Menu Lens Iris PLC Set the iris peak level control value The value could be 000 255 Default value 23X color mono camera 016 NOTE Keep the default value is strongly recommended DAY NIGHT Main Menu Lens Day Night Set the dome color mono chrome switching mode Color mode is suitable to work in daytime because it needs higher illumination Light sens...

Page 28: ...1 150 1 100 1 50 1 25 1 12 1 6 1 3 1 1 5 Set the number of second of shutter time EXPOSURE Main Menu Camera Shutter Exposure means amount of light that reaches the image sensor The smaller exposure value is the larger amount of light reaches and the brighter the images will be The value options are Off Set auto exposure Default setting F1 6 F2 2 F3 2 F4 4 F6 4 F8 8 F 1 2 F 1 7 F 2 4 F 3 4 Choose o...

Page 29: ...ght is bright the objects in the center of the picture may appear dark The dome can auto adjust the brightness of the whole image according to the brightness of center point Thus backlight compensation can increase the brightness of the objects in the center of the picture If the backlight is too dark the object on the center of the picture may appear dark So backlight compensation can decrease th...

Page 30: ...ns are as below Off Disable this function default setting 01 32 Times greater than original speed PROPORTIONAL P T Main Menu Pan Tilt Proportional P T The dome moves at a speed of certain degree per second Objects on screen move much faster in wide scope than in tele scope Even too faster in some case This function decreases the dome movement speed while zooming in On Enable default setting Off Di...

Page 31: ...ick right to desired bit and move the joystick up or down to select desired letter NOTE You can edit 16 bits of letters at most If you are not familiar with the editing please refer to Operation Instruction SETTING Select this item to set the preset position and zoom The following menu will pop up when Set Current is selected Move to the desired position and zoom to a suitable level call preset 1 ...

Page 32: ...to preset 003 and dwell for 2 seconds Move joystick left or right to select editing item Move up or down to change value In the above example the tour starts from preset 1 dwells for 1 second then goes to preset 2 dwell for 5 seconds then preset 3 for 2 seconds and finally preset 4 for 1 second Save and Back Save the tour and exit Cancel and Back Quit without saving NOTE When a preset dwell time i...

Page 33: ...options are 001 004 Record Record pattern Test Test recorded pattern Run Run Pattern until other command received Back Back to upper level menu When getting into Record following menu pop up User can operate dome doing pan tilt zoom as needed The system records the operation To end recording user can call preset 1 to confirm The current pattern recording is finished EVC TP SO453ARW EVC TP SO448AN ...

Page 34: ...f site A Following menu will pop up Move the camera to the desired position and call preset 1 to save Right Position set another site s position Set it in the same way as Left Position Cruise Speed Set the scanning speed camera movement speed Value ranges from 001 to 255 the greater number represents the higher speed Move joystick right to select up or down to change the value Run Start the curren...

Page 35: ...it Set the position of the first point The following picture shows the setting menu The setting procedure is the same as setting preset Move the camera to a particular position and call preset 1 to save Right Limit Set another point s position Set it in the same way as Left Limit Remove Current Delete current zone setting Speed Set the scanning speed camera movement speed Value ranges from 001 to ...

Page 36: ...001 255 Off Disable this function 001 255 Auto run a function after the number seconds of idle time Park Action Park action refers to the function that system will automatically run when park time is up The function could be Off Disable this function Pre 001 220 Call preset 001 220 Scan 001 004 Run auto scan 001 004 Tour 001 004 Run tour 001 004 Pat 001 004 Run pattern 001 004 In this example syst...

Page 37: ... Move joystick to the area where the masking will be Call preset 1 to save Move joystick up or down left or right to position the mask Call preset 1 to save Move joystick right or down to adjust the size of the black square call preset 1 to save NOTE Match the top left angle of the black square to desired position because the black square can expand down and right only Remove Mask Remove current m...

Page 38: ...alarm is activated the doom will run pattern 3 when the third alarm is activated the doom will run scan 2 When the fourth alarm is activated the doom will run tour 1 ALARM OUT 1 2 Alarm out relays the alarm input signal to other devices e g light and DVR Change the option to switch the alarm output ON or OFF Default setting is OFF Arm Disarm Arm or disarm the alarm system and show the status Inter...

Page 39: ...for resetting the dome after changing the dipswitch setting The new setting works only after reboot finishes Led Flashing green light means control commands reach the dome Red light is on when effective command received This model of speed dome supports multi protocol The set ting chart is shown below Switch Number 1 2 3 4 5 6 7 8 ERNITEC YAAN ON ALEC ON PELCO_PD ON ON PELCO_C ON VCL ON ON MOLYNX ...

Page 40: ...d The default broadcast ID is 255 SW2 is for dome ID setting The setting is strictly according to binary system If you are not familiar with binary system please look up the address setting chart Address setting chart ID B1 B2 B3 B4 B5 B6 B7 B8 1 ON 2 ON 3 ON ON 4 ON 5 ON ON 6 ON ON 7 ON ON ON 8 ON 9 ON ON 10 ON ON 11 ON ON ON 12 ON ON 13 ON ON ON 14 ON ON ON 15 ON ON ON ON 16 ON 17 ON ON 18 ON ON...

Page 41: ...N ON 96 ON ON 97 ON ON ON 98 ON ON ON 99 ON ON ON ON 100 ON ON ON 101 ON ON ON ON 102 ON ON ON ON Soft Add ON ON ON ON ON ON ON ON ID B1 B2 B3 B4 B5 B6 B7 B8 103 ON ON ON ON ON 104 ON ON ON 105 ON ON ON ON 106 ON ON ON ON 107 ON ON ON ON ON 108 ON ON ON ON 109 ON ON ON ON ON 110 ON ON ON ON ON 111 ON ON ON ON ON ON 112 ON ON ON 113 ON ON ON ON 114 ON ON ON ON 115 ON ON ON ON ON 116 ON ON ON ON 117...

Page 42: ... 144 ON ON 145 ON ON ON 146 ON ON ON 147 ON ON ON ON 148 ON ON ON 149 ON ON ON ON 150 ON ON ON ON 151 ON ON ON ON ON 152 ON ON ON 153 ON ON ON ON Soft Add ON ON ON ON ON ON ON ON EVC TP SO453ARW EVC TP SO448AN www eurovideo cctv com 42 ...

Page 43: ...199 ON ON ON ON ON 200 ON ON ON 201 ON ON ON ON 202 ON ON ON ON 203 ON ON ON ON ON 204 ON ON ON ON 205 ON ON ON ON ON Soft Add ON ON ON ON ON ON ON ON ID B1 B2 B3 B4 B5 B6 B7 B8 206 ON ON ON ON ON 207 ON ON ON ON ON ON 208 ON ON ON 209 ON ON ON ON 210 ON ON ON ON 211 ON ON ON ON ON 212 ON ON ON ON 213 ON ON ON ON ON 214 ON ON ON ON ON 215 ON ON ON ON ON ON 216 ON ON ON ON 217 ON ON ON ON ON 218 ON...

Page 44: ...248 ON ON ON ON ON 249 ON ON ON ON ON ON 250 ON ON ON ON ON ON 251 ON ON ON ON ON ON ON 252 ON ON ON ON ON ON 253 ON ON ON ON ON ON ON 254 ON ON ON ON ON ON ON Soft Add ON ON ON ON ON ON ON ON EVC TP SO453ARW EVC TP SO448AN www eurovideo cctv com 44 ...

Page 45: ...JP2 the termination resistor is unconnected 2 3 1 2 O N O FF Alarm output method setting There are two alarm output methods NO and NC NO means normal state is open circuit the circuit will be closed when an alarm comes in NC means the contrary When choosing the first and second pins in JP4 and JP5 the alarm output state is NO When choosing the second and third pins in JP4 and JP5 the alarm output ...

Page 46: ...10 For example a set of equipment with nominal power as 80VA installed 35 feet 10m away from transformer needs a wire with a minimum diameter of 0 8000mm EVC TP SO453ARW EVC TP SO448AN www eurovideo cctv com 46 0 80001 0001 2502 00010283 86 451 137 716 218 1811 551 20141 42 225 68 358 109 905 275 3094 28 150 45 238 72 603 183 4070 21 112 34 179 54 452 137 5056 17 90 27 143 43 362 110 6047 14 75 22...

Page 47: ...it Distance 2400BPS 1200m 4800BPS 1000m 9600BPS 800m In case of thinner cables or installs the dome in an environment with strong electromagnetic interference or connects large number of equipment to the RS485 Bus the maximum transmitting distance will be decreased 3 Connection and termination resistor 3 1 The RS485 standards require daisy chain connection between the equipment There must be termi...

Page 48: ...e 5 RS485 Trouble Possible Cause Solution Dome can do self testing but cannot be controlled 1 The address and baud rate settings of dome are not in conformity with those of controller 2 The and connection of RS485 Bus is incorrect 3 Wiring is not fully seated 4 There is breakage in the middle section of the RS485 Bus 1 Change the address and baud rate of controller or dome 2 Correct the connection...

Page 49: ...king properly Check all power related cable Examine the power on the dome side making sure it is above 16 V Self test is ok but dome can not be controlled Wrong dip switch setting Control cable reversely connected or disconnected Set the dip switch correctly according to operation manual Check the control cable making sure it is correctly and firmly connected Fan speed under 1000 rps Fan not firml...

Page 50: ...ey wire is forbidden in such circumstances In strong thunderstorm or high faradic zone such as high voltage transformer substation extra strong lightning proof equipment must be installed Take the building lightning proof requirements into account to design the lightning proof and grounding of outdoor equipment and cable laying out in accordance with the national and industrial standards The syste...

Page 51: ...ranty period the factory assures the user a lifetime payable service 2 Products Information Should a product require service during the warranty period please contact the factory to request an RAN number and ship the product to factory with the following information Product mode and serial number Date of purchase purchase order number sales confirmation number and invoice number Detailed descripti...

Reviews: