TS301;351 TS301/45;351/45 - 8 -
SEP. 2007
ENGLISH
-
ELECTRICAL SAFETY:
Operate this machine only on a supply equipped with a 30 mA earthed current-limiting earth leakage relay.
-
The RCCB must be used correctly, including testing it regularly. For tools supplied with an integral
RCCB in the cable or in the mains plug, if the cable or plug has been damaged, repairs must be carried
out by the manufacturer, one of his agents or by a qualified repair workshop to avoid any risks resulting
from errors.
-
Make sure that the mains voltage corresponds with that marked on the manufacturer’s plate on the
machine.
-
Three- phase motor
Make sure that the motor rotates in the same direction as the arrow on the blade guard: If the motor does
not turn in the direction required, swap two of the supply leads.
-
Use the following types of plug, single phase 2 P + E, according to the corresponding voltage.
-
Extension lead: Cable size sufficient for the electrical power, connection to the mains by a H07 RNF
type cable of the following size: 3 x 2.5 mm² up to 50m for 230V.
Always pay extreme care and attention to the preparation of the machine before starting up.
Remove all adjustment tools and wrenches from floor and machine.
Always keep blade guard in place.
•
Fill the water tank.
•
The water pump should be covered with water all the times as without it there is no cooling and it will
overheat and burn.
As each machine is fitted with a self-priming pump, the water is sprayed onto the blade as soon as the
machine starts.
To start the machine press the green button.
To stop the machine, press the red button.
ELECTRICAL CONNECTION
OPERATION
Ensure that the water supply is abundant, when cutting wet.