background image

9

OPERATING INSTRUCTIONS

6. Remove the belt cover (Fig. 30, #1)
7. Lift the right side of the brush bar first 

and then lift the left hand side.
(Fig. 30 #2, #3)

8. Remove the brush bar from the power 

head. (Fig. 30, #4)

9. Carefully remove any belt residue that 

may exist in the belt area before 
replacing with a new belt.

10. Remove the worn or broken belt from 

the motor drive shaft.

11. Loop the new belt first over the motor 

drive shaft and then over the agitator 
pulley.  

Fig. 30

Clearing the Hose Handle

If the suction is still reduced, check the 
hose handle for blockages.
1. Unplug the unit and remove hose 

handle to check for any blockage. 

2. Clear the blockage from the opening, 

of the hose handle. (Fig. 26) 

Never

insert sharp objects into an opening to 
clear.

3. Verify that extension tube is clear by 

holding it up to the light to see if there 
is any debris blocking the extension 
tube.

4. Plug in unit and resume vacuuming.

Clear
Blockage

Fig. 26

5. With the unit still lying down, turn the 

unit over and lift the power head cover 
starting from the back of the power 
head. (Fig. 29)

Fig. 29

Fig. 27

Base Plate

Lower Plate

Fig. 28

Cleaning & Changing the Belt

Warning:

To reduce the risk of 

electric shock, the power cord must 

be disconnected before removing the 
dust cup, HEPA filter,changing the filters 
or performing maintenance/trouble 
shooting checks.
Occasionally the power nozzle drive belt 
will require changing, the frequency will 
depend upon the amount of use your 
vacuum sees.
1.

Turn the vacuum "Off" and unplug 
from power supply.

2.

Turn the vacuum upside down on a 
flat level surface.

3.

Using a Philips screw driver, 
remove the four (4) screws that 
attach the base plate to the lower 
plate. (Fig. 27)

4. After you have removed the base plate, 

remove the remaining five (5) screws 
from the lower plate using a Philips 
screw driver. (Fig. 28)

Pose des Accessoires

1. Pour attacher les 

accessoires à la 
poignée, retirez la 
poignée de 
l’appareil et
insérez-y 
l’accessoire
désiré (Fig. 7).

2. Si vous désirez 

attachez 
l’accessoire 
au tube télescopique pour une 
meilleure amplitude, retirez le 
tube et insérez-y l’accessoire 
(Fig. 8).

CONSIGNES D’UTILISATION

AVERTISSEMENT:

Retirez 

toujours la fiche d’alimentation de la 

prise murale avant d’installer ou de retirer 
des accessoires.

Insérez le Tube Télescopique au 
Corps de l’Appareil

1. Insérez le tube télescopique dans 

l’ouverture située sur le dessus de 
l’appareil. Assurez-vous que le tube 
s’emboîte bien dans l’ouverture. 
(Fig. 1)

2. Insérez la poignée dans l’ouverture 

supérieure du tube télescopique en 
vous assurant que la tige de 
verrouillage de la poignée est bien en 
place. (Fig. 2)

3.  Pour retirer la poignée, appuyez sur 

sa tige de verrouillage et tirez la 
poignée vers le haut. (Fig. 3)

4.  Pour retirer le tube télescopique, 

appuyez sur le bouton de relâche de 
la poignée situé à l’arrière de 
l’appareil et levez le tube. (Fig. 4)

30

Utilisation Avec les Accessoires

Fig. 7

Suceur plat

Pour radiateurs, fissures, 
coins, plinthes et entre les 
coussins.

Brosse à Épousseter

Pour les meubles, les stores 
vénitiens, les livres,
les abat-jour et les tablettes.

Fig. 8

Pose de l’Étrangleur

1. Placez l’étrangleur dans la fente 

située à l’arrière de l’aspirateur. (Fig. 5)

2. À l’aide d’un tournevis Philips et la vis 

fournie, attachez l’étrangleur à 
l’aspirateur. (Fig. 6)

Fig. 5

Fig. 6

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Tube

télescopique

Tige de 

verrouillage 

de la 

poignée

Lever

Pousser

Lever

Summary of Contents for SHARK V1310PT

Page 1: ...parateur non autoris par EURO PRO Operating LLC Cette garantie couvre l acheteur initial du produit et exclut toute autre garantie juridique ou conventionnelle Le cas ch ant EURO PRO Operating LLC n e...

Page 2: ...unattended while connected 9 Keep hair loose clothing fingers and all parts of body away from opening and moving parts 10 Do not use to pick up flammable or combustible liquids such as gasoline or use...

Page 3: ...R initialisez le disjoncteur ou remplacez le fusible L aspirateur n aspire pas 1 Coupelle pleine ou obstru e 2 Mauvais r glage de la hauteur des poils 3 Bec obstru 4 Orifice d entr e de poussi re obst...

Page 4: ...oucement l appareil 16 Remplacer la plaque inf rieur en vissant les quatre 4 vis externes en premier 17 Pour visser la vis du centre tenir le bouton de r glage de la hauteur du tapis de l ext rieur et...

Page 5: ...et levez le panneau de l lectrobrosse en prenant appui l arri re de l lectrobrosse Fig 29 Fig 29 La courroie d entra nement du bec souffleur doit tre remplac e occasionnellement La fr quence varie sel...

Page 6: ...ppareil refroidi pendant 45 minutes branchez le et appuyez sur le bouton On Off L aspirateur devrait red marrer Si l aspirateur ne d marre toujours pas contactez le service la client le au 1 866 826 6...

Page 7: ...ance AVERTISSEMENT Videz toujours la coupelle et nettoyez toujours le filtre HEPA et le filtre d bris avant chaque utilisation et pendant l usage prolong Ne faites jamais d border la coupelle Retirez...

Page 8: ...adhering to the frame Fig 20 Do NOT place in dishwasher CONSIGNES D UTILISATION Enroulage et D roulage du 32 Cordon d Alimentation Cet appareil est dot d une fonction pratique de rangement du cordon...

Page 9: ...anchez le avant de r gler la hauteur du tapis Le devant de l aspirateur pr sente une poign e qui l ve et abaisse l lectrobrosse motoris e afin de correspondre au type de tapis Pendant que l aspirateur...

Page 10: ...a Philips screw driver remove the four 4 screws that attach the base plate to the lower plate Fig 27 4 After you have removed the base plate remove the remaining five 5 screws from the lower plate us...

Page 11: ...lug from wall outlet 2 With a flat head screw driver snap off the lens cover by pressing down on the two notches on the lens cover Fig 31 3 Lift off the head light lens 4 Remove the light bulb by pull...

Page 12: ...er Brush Does Not Rotate Or Rotates Slowly 1 Rotating brush turbine or elbow obstructed 2 Belt broken 3 Hose obstructed 4 HEPA filter clogged 1 Clear obstructions 2 Call Customer Service 3 Clear obstr...

Page 13: ...de tout ce qui pourrait r duire le d bit d air Rangez l appareil l int rieur dans un endroit frais et sec Assurez vous que votre espace de travail est bien clair Gardez votre visage et votre corps l a...

Page 14: ...ode Model V1310PT 13 Model V1310PT Impreso en China GARANT A LIMITADA DE UN 1 A O EURO PRO Operating LLC garantiza este producto contra defectos de materiales y mano de obra por un t rmino de un 1 a o...

Page 15: ...el sistema desatendido mientras est enchufado 9 Mantenga el cabello la ropa suelta los dedos y toda parte del cuerpo alejados de las aberturas y de las partes m viles 10 No utilizar para recoger l qui...

Page 16: ...encendido una vez 4 Recomponer el termostato del motor 5 Recomponer la llave t rmica o cambiar el fusible Aspiradora no absorbe 1 Recipiente de la tierra lleno o tapado 2 Ajuste de altura inadecuado 3...

Page 17: ...Presi nelo firmemente para asegurarse de que est insertado completamente 13 Verifique que la correa est centrada en la polea del agitador y que el cepillo pueda girar 14 Vuelva a colocar la cubierta...

Page 18: ...ar la base quite los cinco 5 tornillos restantes de la placa inferior con un destornillador Philips Fig 28 Base Placa inferior Fig 28 Limpieza del Mango de la Manguera Si contin a notando una reducci...

Page 19: ...rre la cubierta superior del cepillo y deslice la palanca de traba hacia atr s para trabar la cubierta Fig 11 INSTRUCCIONES DE USO Termostato del Motor Importante Esta unidad est equipada con un termo...

Page 20: ...erficie dura hasta que no salga m s tierra Fig 17 Fig 15 ADVERTENCIA Siempre vac e el recipiente de la tierra y limpie el filtro HEPA y el filtro de deshechos luego de cada uso y durante usos prolonga...

Reviews: