Troubleshooting
AirCop
51 from 135
20001.1
12/5/2020
Original operating instructions
14
Troubleshooting
Error
Troubleshooting
AirCop
does not light
up
1. USB plug inserted correctly.
2. Tried other socket.
3. If the error persists, return it to the
manufacturer.
Measuring chamber was deformed by mechanical
shock:
Recalibration by the customer possible. (14.1)
Measuring chamber was deformed by mechanical
shock:
Recalibration by the customer possible. (14.1)
AirCop
remains white
AirCop
boots-up
normally but remains
jaune or red, even when
exposed to fresh air
AirCop
is white for a
few seconds and then
flashes white and red
Sensor was not found. The device must be returned to
the manufacturer.
AirCop
is white for a
few seconds and then
flashes white and blue
Sensor was found, but does not provide any values:
1. Plugging in and unplugging the device
2. If error persists, return the device to the
manufacturer
AirCop
is always jaune
or red
Measuring chamber was deformed by mechanical
shock:
Recalibration by the customer possible. (14.1)
Self-calibration of the electric device
To guarantee the best possible CO2 measurement, a self-calibrating NDIR high-
performance sensor is installed in the
AirCop
. This sensor detects the CO2
content of the ambient air and stores the lowest value every day. This value is
interpreted as the CO2 content of the fresh air. This assumes that the room is well
ventilated once a day. This process is repeated daily. If the daily stored lowest
value deviates less than +- 25 ppm in 7 consecutive days, the sensor calibrates
itself to this value. The operation is shown on the following infographics: