33
2105274-12-08/20 (Translation of the original operating instructions)
Operating instructions
Non-Contact Safety System CES-AZ-UES-…
EN
Terminal assignment
Read head with plug connector
H11 H12 SH1
1
3
4
BN
WH
Shield
View on the plug
connector of the
read head
Evaluation unit
CES-AZ-UES-…
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Fortron, reinforced thermoplastic, fully encapsulated
Dimensions
42 x 25 x 12
mm
Weight (incl. 10 m cable)
0.3
kg
Ambient temperature
-25
-
+70
°C
Degree of protection
IP67/IP69K
Installation orientation
Any
Method of operation
Inductive
Power supply
Via evaluation unit
In combination with actuator CES-A-BBA
Assured release distance S
ar
-
-
26
mm
Actuating range for center offset m = 0
1)
- Switch-on distance
-
15
-
- Assured switch-on distance S
ao
10
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s for side approach direction
3
-
-
In combination with actuator CES-A-BDA-20
Assured release distance S
ar
-
-
33
mm
Actuating range for center offset m = 0
2)
- Switch-on distance
-
16
-
- Assured switch-on distance S
ao
11
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s for side approach direction
4
-
-
In combination with actuator CES-A-BDA-18
Assured release distance S
ar
-
-
32
mm
Actuating range for center offset m = 0
1)
- Switch-on distance
-
16
-
- Assured switch-on distance S
ao
10
-
-
- Switching hysteresis
0.5
1.4
-
Minimum distance s for side approach direction
5
-
-
Connection
M8 plug connector, 3-pin
Connecting cable
-
-
25
m
1) These values apply to surface installation of the read head and the actuator.
2) These values apply to non-metallic surrounding material. Other materials on request.