Operating instructions
Non-Contact Safety System CES-AZ-UES-…
10
(Translation of the original operating instructions) 2105274-12-08/20
6.1. Block diagrams of CES-AZ-UES-…
CES-AZ-UES-01B
0V
TST
UB
CES-AZ-UES-01B
105139
J
SH1
O1
Read-
head
1
H11
Trans-
ponder
H12
EUCHNER
DIA
23 24
13 14
Y1
Y2 S
K2
+
K1
+
Activation of the
teach-in operation
with jumper on
J, 0V.
UB, 0V
Power supply
J, 0V
Jumper for teach-in operation
H11/H12
Read head 1 connection
SH1
Read head 1 shield
TST
18)
O1
Semiconductor monitoring output
DIA
Diagnostic output
13, 14
Connection for relay contact A,
safety relay enable
23, 24
Connection for relay contact B,
safety relay enable
Y1, Y2
Feedback loop
S
Start button connection
(monitoring of the falling edge)
CES-AZ-UES-02B
0V
TST
UB
CES-AZ-UES-02B
105140
J1 J2 SH1
O1
Read-
head
1
H11
Trans-
ponder
O2
H12
EUCHNER
SH2
Read-
head
2
H21
DIA
Trans-
ponder
H22
23 24
13 14
Y1
Y2 S
K2
+
K1
+
Activation of the
teach-in operation
with jumper on
J1, J2.
UB, 0V
Power supply
J1, J2
Jumper for teach-in operation
H11/H12, H21/H22 Connection for read heads 1 and
2
SH1, SH2
Shield for read heads 1 and 2
TST
18)
O1, O2
Semiconductor monitoring
outputs
DIA
Diagnostic output
13, 14
Connection for relay contact A,
safety relay enable
23, 24
Connection for relay contact B,
safety relay enable
Y1, Y2
Feedback loop
S
Start button connection
(monitoring of the falling edge)
CES-AZ-UES-04B
0V
TST
UB
CES-AZ-UES-04B
105141
J1 J2 SH1
O1
Read-
head
1
H11
Trans-
ponder
O2
H12
EUCHNER
O3
SH2
O4
Read-
head
2
H21
DIA
Trans-
ponder
H22
23
SH3
24
Read-
head
3
H31
Trans-
ponder
13
H32
14
SH4
Y1
Read-
head
4
H41
Y2
Trans-
ponder
H42
S
K2
+
K1
+
Activation of the
teach-in operation
with jumper on
J1, J2.
UB, 0V
Power supply
J1, J2
Jumper for teach-in operation
H11/H12...H41/H42 Connection for read heads 1...4
SH1...SH4
Shield for read heads 1...4
TST
18)
O1...O4
Semiconductor monitoring
outputs
DIA
Diagnostic output
13, 14
Connection for relay contact A,
safety relay enable
23, 24
Connection for relay contact B,
safety relay enable
Y1, Y2
Feedback loop
S
Start button connection
(monitoring of the falling edge)