![EUCHNER 100105 Operating Instructions Manual Download Page 8](http://html.mh-extra.com/html/euchner/100105/100105_operating-instructions-manual_2434804008.webp)
Operating Instructions
Safety Switch STP-BI…
8
Subject to technical modifications; no r
esponsibility is accepted for the accuracy of this information.
© EUCHNER GmbH + Co. KG
2100209‑09‑12/17 (translation of the original operating instructions)
Figure 4: Dimension drawing for STP‑BI… without insertion funnel and STP‑BI… with insertion funnel
h
35,5
45,5
30
4
194
9
16
4
0,5
0,5
v
19
19
4
L
Actuating head with insertion funnel
M = 0.8 Nm
Necessary minimum permissible overtravel
Approach direction
Actuator S
standard
Actuator L
insertion funnel
Horizontal (h)
24.5 + 5
28.5 + 5
Vertical (v)
24.5 + 5
28.5 + 5
With escape release (short/long actuator shaft)
61,5
74,7
67
,5
53
36
4
∅
14
20
31
M
4
Short actuator shaft
Long actuator shaft
Always install the escape
release lever on the
recessed side
Establish a positive
connection between the
shaft and lever.
Key to symbols
/
Guard locking ready for operation
/
Guard locking released
With plug connector SR11
30
ca. 28
Locking screw
Auxiliary release
Auxiliary release with triangu‑
lar wedge
(two triangular keys included)
)x
3(
5,
1x
02
M
30
<40>
h
44
1
5,
53
5,
14
30
4
09
1
22
16
<42>
0,5
v
For M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
M = 1.5 Nm
M = 0.5 Nm