Fig. 10
GRINDING weight-based versions (W)
All W-versions may be operated in time- or weight-based as well as in SCALE-
only-mode!
Fig. 11
Fig. 12
Time-based Mode
Scale-only-mode
Weight-based Mode
NOTE
: From Scale-only-mode, the system will always return to the mode
it was in before switching.
CHANGE of MODE - Combinations:
Weight (gr) to Time(Sec) and back:
STOP and 1
(at least 5 sec)
Weight (gr) or Time (Sec) to Scale-only and back:
STOP
(at least 5 sec)
Weight-based GRINDING
WEIGHT-BASED:
Press the desired Preset-
button (1, 2, 3). Display will show the
programmed weight in grams. Press START.
While grinding, the display is showing the
corresponding grams and comes to a halt
when the custom weight is reached. The
motor will stop, and the display will reset to
the programmed weight.
The etzMAX will go into
SLEEP MODE
after 4 hours of non-use. To reactivate the
grinder, press any button on the User Interface.
SCALE ONLY
For using the scale independently from grinding, press STOP for at least 5
seconds.
While in SCALE-mode, all LEDs stay illuminated and the Display
shows 0.0 (Fig. 11). To return to weight-based-grinding, press STOP for 5
seconds.
Time-based GRINDING (W-version)
To switch to time-based mode
, simultaneously press
STOP and 1
for 5
seconds. The display will now show the time in seconds, while a vertical
line on its left side indicates that you are in time-mode (Fig. 12). To return
to WEIGHT-based grinding, press STOP and 1 for 5 seconds.
To pause
the grinding during operation, press
START-button
. By repeatedly
pushing START-button, the target weight may be reached in small steps of 0.1-
0.2g. For grinding in
manual mode (or Purging)
, press and hold START until you
reach the desired weight. Release the START button. To return to automatic
mode, press STOP.