Connection
mode[1:always
online/2:wakeup
online/3:online
upon request]
Configure connection mode. Always
online means after power on it
keeps connected with data center,
and
auto
connects
after
disconnection;
Wakeup
online
means it does not connects after
power on, and dials and connect
when receiving wakeup SMS or
wakeup call(wakeup phone number
and wakeup password need to
configure), and after wakeup online
if there is no data transfer in
continuous 5 minutes it will
disconnect; Online upon request
means it does not connects after
power on, and when data need to be
sent from serial port it will be
triggered to dial and connects data
center, and after online upon
request if there is no data transfer
in continuous 5 minutes it will
disconnect. Online upon request
includes wakeup online functions,
that is, when no data need to be
sent from serial port and it does not
connect after power on, it can be
triggered to dial and connect by
wakeup SMS or wakeup call.
15) Serial Timeout (ms) (20)
Configure serial timeout, 20ms by
default.
16) SMS wakeup password (1234) Configure password used for SMS
wakeup when connection mode is
wakeup online. If SMS wakeup is
required, the SMS used to wakeup
must use this password. At the
same time, this password is also the
password used to configure the
SMS.