background image

 

Operation   

25

 

7.0   Operation 

 

Before placing into operation, follow the safety information in the 
ETS-Lindgren 

Product Information Bulletin

 included with your 

shipment. 

With the assembly of the turntable complete, the Model 2090 Multi-Device 
Controller (or next generation ETS Lindgren controller, if applicable) must be 
connected to the unit and power applied to both the motor base and controller. 
See the controller manual for complete information on connecting the fiber optic 
cable and operating the controller. A manual is included with each controller and 
is also available for download from 

www.ets-lindgren.com

 

26   

 

Operation

 

This page intentionally left blank. 

 

 

List of Assembly Drawings 

 

27

 

Appendix A:  List of Assembly Drawings 

Following is a list of the assembly drawings located in the back of this manual. 
Prior to assembly and installation, review the drawings. Refer to the drawings 
during assembly and installation for detailed information. 

 

2187–2.0:

 2-meter turntable (3 pages) 

 

2187–3.0:

 3-meter turntable (2 pages) 

 

28   

 

List of Assembly Drawings

 

This page intentionally left blank. 

Summary of Contents for 2187

Page 1: ... Contents Notes Cautions and Warnings v 1 0 Introduction 7 Standard Configuration 7 Turntable Assembly 7 Shield Room Feed through 8 Optional Items 8 Infrared Remote Controller 8 Slip Ring 8 EUT Power Outlets 9 Mounted Line Impedance Stabilization Network 9 Additional Fiber Optic Cables 9 ETS Lindgren Product Information Bulletin 9 2 0 Maintenance 11 Recommended Maintenance Schedule 11 6 Month Serv...

Page 2: ...o accommodate customer supplied cabling to and from the EUT To prevent over travel of the turntable in either direction of movement hard limits are provided in the form of pins that actuate switches located below the tabletop These pins allow limits to be set and allow as much as two full rotations Rotation speed can be varied from a controller not included or through the IEEE 488 interface bus St...

Page 3: ...oints within the instrument that could if contacted cause personal injury Only trained service personnel should perform adjustments and or service procedures upon this instrument Capacitors inside this instrument may still be charged even when the instrument is disconnected from the power source Recommended Maintenance Schedule Regular maintenance will prolong the effective operation and reliabili...

Page 4: ...Regularly inspect all equipment for loose fasteners and wear Conduct scheduled maintenance in accordance with the factory recommendations provided Only use replacement parts and fasteners ordered directly from the factory Stay clear of all moving components on this equipment Do not operate turntable while someone is physically on the turntable top Do not at any time place hands or feet in the vici...

Page 5: ...r installation of the turntable directly affects performance The installation of turntables two meters and larger will be performed by factory installation specialists or individuals authorized by ETS Lindgren to perform such work The following installation information is included only to provide an informational overview of the installation process 1 Uncrate all parts and check for shipping damag...

Page 6: ...e Installation in a Concrete Pit Installing in a concrete pit is the same as a paneled floor with the exception of the mounting hardware Instead of the 14 x 1 in square socket flat head screws use 1 4 x 1 75 in Phillips flat head concrete anchors These tools are required for the next stage of installation 1 2 in hammer drill 3 16 x 3 5 in hammer drill bit at minimum Vacuum to clean inside the dril...

Page 7: ...ation on connecting the fiber optic cable and operating the controller A manual is included with each controller and is also available for download from www ets lindgren com 26 Operation This page intentionally left blank List of Assembly Drawings 27 Appendix A List of Assembly Drawings Following is a list of the assembly drawings located in the back of this manual Prior to assembly and installati...

Page 8: ...Point Drive Cedar Park TX USA 78613 Cedar Park TX USA 78613 The products listed below are eligible to bear the CE mark Model 2187 Electric Powered Turntable 2 Meter and 3 Meter with 2088 style motor base APPLICABLE REQUIREMENTS Standard Criteria EN 55011 Group 1 Class B EN 61000 4 2 1995 Level 2 3 4 8 kV EN 61000 4 3 1997 Level 2 3 V m EN 61000 4 4 Level 2 1 0 5 kV ENV 50204 1996 Level 2 3 V m EN ...

Page 9: ...8 11 X 1 3 4 HEX GR5 ZN 33 10 910619 SCREW 5 8 11 X 1 25 SH FLAT SS 32 32 910616 SCREW LEVELING 1 2 13 X 3 SQ HD CU 31 32 910615 NUT 3 8 16 HEX ZINC SERRATED FLANGE 30 4 910603 SCREW 1 4 20 X 7 8 PHIL FLAT SS 29 2 910599 BOLT 3 8 16 X 2 1 2 HEX SS 28 10 910539 WASHER 5 8 LOCK STL ZN SPLIT 27 8 910456 WASHER 1 4 LOCK SS SPLIT 26 8 910436 BOLT 1 4 20 X 1 2 HEX SS 25 2 910411 WASHER 3 8 LOCK STL ZN S...

Page 10: ... 6 3 RMS OR B ETTER FINISH TOLERANC ES ARE DECIMALS ANGLES DRAFTING PERMISSION OF ETS LINDGREN IS PROHIB ITED ANY DUPLIC ATION OF THIS PROPRIETARY INFORMATION WITHOUT EXPRESS WRITTEN DOC UMENT WHOLE OR IN PART DATE TITLE OF SHEET DWG NO An ESCO Technologies Company SC ALE D TM REV 5 19 0 A RELEASED 1 0 2 7 0 6 RB G RB G 117 22 TABLE TOP 121 82 REF 119 12 25 PIT OPENING DIMENSION REF A A REFER TO S...

Page 11: ...34 FLOOR FLANGE TURNTABLE 3 0m AL 14 6 112133 TIEBAR INSIDE TOP 2187 3 0 13 1 111988 TOP SECT4 TURNTABLE 2187 3 0 12 1 111987 TOP SECT3 TURNTABLE 2187 3 0 11 2 111986 TOP SECT2 TURNTABLE 2187 3 0 10 2 111985 TOP SECT1 TURNTABLE 2187 3 0 9 2 111333 RING SPLIT 2187 TURNTABLE 8 12 110405 CONTACTFLAT BRUSH TURNTABLE 7 6 110059 PLUG HOLE TABLETOP 6 1 108925 COVER ACCESS 5 12 106789 FLOOR PLATESPACER 20...

Reviews: