1. LPG gas pressure area:0.2
~
0.7MPa.
2. DO NOT use gasoline as fuel.
3. Connect LPG tube on LPG tank and fasten it.
4. Turn the LGP tank valve to "ON” position - full
open.
5. Screw on the trachea tie-in
6. Check all connections for propane leaks with
soapy water and tighten connections.
7. If air pressure is low change the tank. When
propane pressure is low, replace with a full
tank.
Grounding
Your generator must be properly connected to an
appropriate ground to help prevent electric shock.
A ground terminal connected to the frame of the
generator has been provided on the power panel.
For remote grounding, connect a length of heavy
gauge (14 AWG minimum) copper wire between the
generator ground terminal and a copper rod driven
into the ground. We strongly recommend that you
consult with a qualified electrician to ensure
compliance with local electrical codes.
The engine is equipped with a low-oil-shutoff and
this will stop when the oil level in the crankcase falls
below the threshold level.
Check oil often during the break-in period. Refer to
the Maintenance section for recommended service
intervals.
?
NOTE
The generator rotor has a sealed, pre-lubricated
ball bearing that requires no additional lubrication
for the life of the bearing.
?
NOTE
Use clean, fresh, regular LPG with LPG gas
pressure area:0.2
~
0.7MPa.
DO NOT mix oil with fuel.
DO NOT use gasoline as fuel.
Connect LPG tube on LPG tank and fasten it.
Turn the LGP tank valve to "ON” position - full open.
Screw on the trachea tie-in
Check the LPG to see if it is leaking and then
guarantee it.
When the air-pressure is lower than standard range,
please change LPG tank.
Failure to properly ground the generator can result
in electric shock.