7/9
10. Application
1) When high-precision measurement is required, as in a navigation system, use the output of this
sensor through an A/D converter as shown below.
2) Positive voltage (+) and negative voltage (-) are obtained in the clockwise and counter clockwise
directions, respectively, with the static output as a reference.
3) Always use A/D converter of 12 bits or more. Resolution of A/D converter will affect measurement
accuracy. Please choose a proper resolution according to the application.
4) The sampling frequency used for measurement should be 50 times/sec Min. Sampling frequency
will affect measurement accuracy. Please choose a proper sampling frequency according to the
application.
5) It is possible to derive relative angle variation from integrating the output voltage.
A/D
converter
Micro
processor
Sensor
output
+
-
Senso
r
ENV-05F