4/9
5. Installation
1) Install the sensor with the bottom face as reference.
2) Install the sensor vertically with respect to the rotating surface. (90 ± 5 deg)
3) Install the sensor in a location free from vibration.
4) Install the sensor in a place free from substantial variations in temperature.
5) When installing the sensor, solder four tabs and terminals on PCB (t=1.6mm).
6) Observe the following rules. If not, characteristics might vary due to soldering heat.
Soldering iron
Flow soldering
Terminal : 350±5deg C, 5s or less.
Tab : 350±5deg C, 10s or less.
Soldering : 250±5deg C, 5s or less.
Preheating :105±10degC,2min.or less.
7) Tabs can be bent only once.
6. Terminal connection
Terminal descriptions
Please refer to page 3 for terminals.
Terminal
Symbol
Descriptions
1
+Vcc
Supply voltage
(input)
2
GND
Ground
(common)
3
Vout
Sensor output
(output)
6.25
6.25
2.54
11.2
0.8
18.6
3.0
3-ø1.0
2.15
1.3
Unit : mm
1.3
www.DataSheet4U.com