background image

E T C   I n s t a l l a t i o n   G u i d e

Paradigm P-LCD Series

Unison  Paradigm  Touchscreen  Rack  Panel

Page 3 of 4

Electronic Theatre Controls, Inc.

Step 2:

Plug the LinkPower connector into the two pin LinkPower receptacle on the termination 
PCB.

Step 3:

Terminate the installed Auxiliary power wire to the red and black Auxiliary power pigtail 
wires. Using two Wago connectors connect the (typically red) installed wire(s) with red 
pigtail wire and connect the (typically black) installed wire(s) with black pigtail wire.

Step 4:

Plug the Auxiliary power connector into the two pin Aux power receptacle on the 
termination PCB.

Installing the Termination PCB to the Rack Panel

Step 1:

Position the PCB on the four standoffs on the back of the rack panel and secure with two 

M3x10mm pan head screws on the RJ11 side of the PCB only.

Step 2:

Place the bracket and RJ45 assembly (if used) on top of the PCB. Secure the PCB to the 
backbox through the remaining holes in the PCB with two M3x10mm pan head screws.

Step 3:

A ground connection is required for all Touchscreen assemblies. Using one three position 
Wago connector, connect the (typically green and yellow) installed wire(s) with the ground 
wire pigtail (with attached spade), provided in the installation kit, and the ground wire 
attached to the rack panel.

N o t e :

The termination PCB can be installed in any orientation to accommodate wiring.

Installed ground wire
Ground wire pigtail (spade connector to the termination PCB)
Ground wire pigtail (ring terminal connected to the rear rack panel)

Summary of Contents for Paradigm P-LCD Series

Page 1: ... a rack panel which is shipped separately The Touchscreen is also available in locking cover and wall mount configurations The Touchscreen is powered by either LinkPower and Auxiliary power or PoE Power Over Ethernet 802 3af Echelon LinkPower LinkConnect control network utilizing Belden 8471 or approved equal and 24 Vdc Auxiliary power two 16 AWG 1 5mm2 wires PoE Power over Ethernet 802 3af utiliz...

Page 2: ...nd black twisted pair and ground wire pigtails Strip the ends of each wire both installed control wires and pigtail wires approximately 3 8 10mm Step 1 Terminate the installed LinkPower wiring to the white and black LinkPower pigtail Using two Wago connectors connect typically white installed wire s with white pigtail wire and connect the typically black installed wire s with black pigtail wire as...

Page 3: ...ep 1 Position the PCB on the four standoffs on the back of the rack panel and secure with two M3x10mm pan head screws on the RJ11 side of the PCB only Step 2 Place the bracket and RJ45 assembly if used on top of the PCB Secure the PCB to the backbox through the remaining holes in the PCB with two M3x10mm pan head screws Step 3 A ground connection is required for all Touchscreen assemblies Using on...

Page 4: ...e collar Then lift the bottom upward slightly and rotate outward Indicators After the Touchscreen has been powered up the appropriate LEDs on the service panel on the bottom of the Touchscreen illuminate The LCD displays a startup screen a few seconds after booting I O Indicators Reset when pressed resets the Portable LCD software Mode press once for Setup menu Press and hold for 4 seconds to cali...

Reviews:

Related manuals for Paradigm P-LCD Series