background image

Planning the installation

TSE55 requires a minimum mounting depth of 
20mm from the front wall surface plus room 
for cable/s. Power is supplied by Power Over 
Ethernet (PoE). PoE must meet the IEEE 802.3af 
standard. TSE55 connects to the local network 
via a hard wired Ethernet connection. 

Installation

TSE55 has been designed to mount to a Standard UK 
single gang back box, a standard European single gang 
back box as well as a standard US NEMA single gang 
back box. Minimum depth: 47mm
The mounting frame, included with this unit, should be 
attached to the back box using the screws supplied 
with the back box. 

Installing the mounting frame

TSE55 includes a mounting frame that MUST be used 
for this installation.
Using the screws supplied with the backbox, mount 
the mounting bracket onto the back box

Mounting height

The recommend mounting height for the 

TSE55 is 145 cm -165 cm above the finished 
floor to the center of the unit.

TSE55 - Colour Touchscreen

Installation guide

Tighten the 2 captive 
screws (one at each side) 
to secure the TSE55 to 
the mounting bracket

Mounting the TSE55

Align the mounting frame 
hooks with the TSE55 
mounting slots and gently 
push the TSE55 unit onto 
the mounting bracket.
Make sure the mounting 
hooks are properly 
engaged.

UK

Back Box

TSE55

EURO

NEMA

Mounting Bracket

PoE and Data Connection (RJ45)

Reviews: