Environment
The ColorSource Linear operates in ambient temperatures of 0°C–40°C and
comes with a variable-speed fan. The ColorSourceLinear is for indoor use
only.
•
Maximum recommended ambient operating temperature: Ta = 40°C
(104°F)
•
Maximum anticipated external surface temperature at 40°C ambient:
Tmax = 80°C (176°F)
•
External temperatures after 5 minutes of full-brightness operation at
25°C (77°F) ambient: 36°C (97°F)
•
External Temperature (steady state achieved) at 25°C (77°F): 48°C
(118°F)
Electrical
•
Operates between 100 V and 240 VAC at a frequency of 50/60 Hz.
•
Maximum power consumption:
-
Linear 1: 120 W
-
Linear 2: 240 W
-
Linear 4: 480 W
•
Up to 9 cells (0.5 m segments) may be linked via power thru connector.
•
Up to 10 cells (0.5 m segments) total per circuit when used with an
R20 Relay Module or Unison Echo Relay Panel. Consult breaker trip
curves when used with other equipment. Requires power from a non-
dimmable source.
•
Inrush (Linear 1/Linear 2/Linear 4):
-
120 V: 35 A/35.6 A/67.5 A (first half-cycle)
-
240 V: 49 A/85.6 A/153 A (first half-cycle)
ColorSource Linear
Page 3 of 20