background image

ETC Installation Guide

ColorSource Linear v1.7

Install Secondary Lenses

2: Pivot

1: Loosen

You can use several optional
accessories with the
ColorSource Linear, including
secondary lenses (horizontal,
vertical, and round). You can
use either a single lens or two
lenses simultaneously, and
you can install them from
either end of the fixture.

For the Linear 2 and Linear 4
fixtures, order one accessory
for each 0.5 meter segment
(cell) of the fixture.

Spacer

Spacers for secondary lenses are included with the fixture. Use
these spacers to hold the accessories in position when multiple
lenses are used in the Linear 2 and Linear 4 fixtures.

1.

Loosen the thumbscrew on the access panel on either
end of the fixture.

2.

Pivot the access panel until you can access the slots
above the LEDs.

3.

Spacer

Secondary 

lens

Secondary 
lens

Slide the secondary lens
(or lenses) into either of
the slots above the LEDs.

4.

For the Linear 2 and
Linear 4 fixtures, position
spacers between the
lenses for the cells (in the
same slot as the lenses).
See image at left.

5.

Pivot the access panel
back into place and
tighten the thumbscrew.

ColorSource Linear

Page 15 of 20

ETC

Summary of Contents for ColorSource Linear

Page 1: ...020 03 Overview The ColorSource Linear is an affordable LED fixture that uses the RGB L red green blue and lime color system to provide a rich bright light The fixture is available in three lengths Co...

Page 2: ...ing the following READ AND FOLLOW ALL SAFETY INSTRUCTIONS Do not use outdoors Do not let power supply cords touch hot surfaces Do not mount near gas or electric heaters Equipment should be mounted in...

Page 3: ...7 F External Temperature steady state achieved at 25 C 77 F 48 C 118 F Electrical Operates between 100 V and 240 VAC at a frequency of 50 60 Hz Maximum power consumption Linear 1 120 W Linear 2 240 W...

Page 4: ...everal half meter optional accessories with ColorSource Linearfixtures including Secondary lenses horizontal vertical and round Barn doors 7414K1020 Louver 7414K1019 For information on installing seco...

Page 5: ...able anchor point Cutout for cable strain relief Safety Cable Two safety cable anchor points are provided on the fixture housing The anchor points also include two cutouts that can be used for cable s...

Page 6: ...on the following page for reference 1 Plug the power cord into the powerCON In connector on the rear of the fixture 2 Make any power thru cable connections prior to applying a power source 3 Make any...

Page 7: ...n press the Mode button to access the Presets Sequences menu See Play Presets and Sequences on page 12 Adjust the Tilt The fixture can be tilted up and down as needed 1 Loosen but do not remove the tw...

Page 8: ...button to change the DMX control mode 5ch 5 channel mode intensity red green blue and strobe This is the default mode dir Direct emitter control intensity red green blue indigo lime and strobe 1ch 1 c...

Page 9: ...X control mode see Change the DMX Control Mode on the previous page For example if you set the DMX address on the fixture to 100 set the DMX mode to 5 channel and set the Grouping mode to Cell the sta...

Page 10: ...Blue 4 Blue Blue Indigo Cell 2 Red 5 Strobe Lime Green 6 Cell 2 Intensity Strobe Blue 7 Red Cell 2 Intensity 8 Green Red 9 Blue Green 10 Strobe Blue Indigo 11 Lime 12 Strobe Original ColorSource Linea...

Page 11: ...3 Red 8 Green Red Green 9 Blue Green Blue 10 Strobe Blue Indigo Cell 4 Red 11 Cell 3 Intensity Lime Green 12 Red Strobe Blue 13 Green Cell 3 Intensity 14 Blue Red 15 Strobe Green 16 Cell 4 Intensity...

Page 12: ...ixture See Re record Presets on the facing page When a Linear 2 or Linear 4 fixture is in Cell mode you can re record a preset with each cell having a distinct set of values See Set the Grouping Mode...

Page 13: ...esets When you re record presets with the fixture in RGB mode rgb the intensity is set to full and the strobe is turned off See Change the DMX Control Mode on page 8 Adjust the Intensity of Presets 1...

Page 14: ...newer software version or update a ColorSource fixture to a newer software version using UpdaterAtor you can use that fixture to push the newer software version to all connected ColorSource fixtures e...

Page 15: ...ry lenses are included with the fixture Use these spacers to hold the accessories in position when multiple lenses are used in the Linear 2 and Linear 4 fixtures 1 Loosen the thumbscrew on the access...

Page 16: ...unplugged Verify that internal cables are properly connected If the error persists the fixture will need to be returned to the ETC factory contact your local dealer to set up a repair No App Screen to...

Page 17: ...inear 4 Deep Blue 0x0212 DMX Start Address All 0x00F0 Range 1 512 DMX Personality Linear 1 0x00E0 1 5 Channel 2 Direct 3 1 Channel 4 RGB Linear 2 in Group mode Linear 4 in Group mode Linear 2 in Cell...

Page 18: ...ETC Installation Guide ColorSource Linear v1 7 ColorSource Linear Page 18 of 20 ETC...

Page 19: ...ETC Installation Guide ColorSource Linear v1 7 ColorSource Linear Page 19 of 20 ETC...

Page 20: ...cate a problem with the color calibration The fixture will need to be returned to the ETC factory contact your local dealer to set up a repair OtP Screen toggles between OtP and ERR to indicate that t...

Reviews: