ETC Installation Guide
ColorSource Linear v1.7
Restore Factory Defaults
Press and hold the Mode button, Up button, and Down button
simultaneously for 5 seconds. The DMX start address will blink once to
confirm that defaults have been restored.
Error Codes
There are three error codes that may be shown on the user interface.
•
CAL
: Screen toggles between
CAL
and
ERR
to indicate a problem with
the color calibration. The fixture will need to be returned to the ETC
factory; contact your local dealer to set up a repair.
•
OtP
: Screen toggles between
OtP
and
ERR
to indicate that the fixture
has gone into over-temperature protection mode to avoid damaging
the fixture. Once the fixture has self-cooled, the error will automatically
clear.
•
CBL
: Screen toggles between
CBL
and
ERR
to indicate that a control
card or the internal cabling is damaged or unplugged. Verify that
internal cables are properly connected. If the error persists, the fixture
will need to be returned to the ETC factory; contact your local dealer to
set up a repair.
•
No App
: Screen toggles between
no
and
APP
to indicate that the
upgraded fixtures have a software issue. Reload software to clear the
error. If the error persists, contact ETC.
Use RDM
RDM and Grouping Modes
Linear 2 and Linear 4 fixtures in Cell mode contain 2 sub-devices (Linear 2) or
4 sub-devices (Linear 4). Use DMX_BLOCK_ADDRESS to set the DMX address
of the first cell, and the remaining cells will be numbered sequentially from
that starting value.
RDM also allows you to use nonsequential DMX addresses, if desired. The
fixture displays “---” for the DMX address to indicate nonsequential DMX
addressing. If you set up nonsequential DMX addresses and then change the
DMX address at the fixture, however, the fixture will return to sequential DMX
addressing.
Linear 2 and Linear 4 fixtures in Group mode do not use sub-devices.