ETAS
Technical Data
ES441.1 - User Guide
93
8.1.2
Standards and Norms
The module adheres to the following standards and norms
Marking for UKCA conformity (Chapter 8.4 on page 95)
Marking for KCC conformity (Chapter 8.5 on page 95)
Labeling for RoHS (China), see chapter on page 95
Norm
Test
DIN EN 60068-2-1
Premature fatigue cold test
DIN EN 60068-2-2
Premature fatigue heat test
DIN EN 60068-2-13
Negative pressure
DIN EN 60068-2-14 Na
Temperature shock
DIN EN 60068-2-14 Nb
Temperature change:
Temperature: Tu –40 °C / To +120 °C,
Number of cycles: 10,
Unit under test: active
DIN EN 60068-2-56
Humidity storage
DIN EN 60068-30, Variant 1
Climate change
DIN EN 60068-2-64,
ISO 16750-3
Vibration, noise:
3 space axis, test duration 4 h,
Unit under test: active
In addition, the combination was
tested by cascaded modules.
ISO 16750-3, Sec. 4.2.2.2
Mech. shock
3 space axis, half sinus,
Acceleration: 500 m/s²,
Shock duration: 6 ms,
Shocks per direction and axis: 10,
Units under test: active
ISO 16750-3, Sec. 4.3
Drop test
Number of drops: 2,
Height: 1 m,
Surface: concrete, steel
Units under test: passive
ISO 16750-4, Sec. 5.2
Phased temperature test
Symbol
Description