Troubleshooting Problems
ES441.1 - User Guide
84
Measurement
does not start.
Are you being prompted to
carry out an update in the
INCA-Monitorlog or in the
Config-Tool?
Update the modules.
Is there no data from the
module?
Check that your power supply and test
setup correspond to the requirements
listed in section 4.5 on page 28.
Check that the wiring of the hardware
to the PC is correct/intact.
Check that the modules in the module
chain are connected correctly.
You are using the ES4xx Con
-
figuration Tool and the mod
-
ule is supplying no data?
Check whether the position of one or
more modules in the chain has
changed.
Check that you are not using an incor
-
rect A2L file.
Check whether you
have loaded the measure configuration
to the module chain.
Check that you have not assigned the
same IP address to two module chains.
Is the module supplying
usable data?
Check that the sensor is connected cor
-
rectly.
Data is lost during
data transfer.
Are you using WLAN in your
test setup?
WLAN is not permissible within this
ETAS network. Wire your test setup
(ETAS modules and their connection to
the PC) with ETAS cables only.
Are you using the correct
type of network card in your
laptop?
Check whether you are using a PCMCIA
network card in your laptop. PCMCIA
cards with an 8- or 16-bit data bus are
not suitable. Only use PCMCIA cards
with a 32-bit data bus, mini-PCI or
ExpressCards.
Are you operating the ETAS
Daisy Chain modules on a PC
with multi-core processor?
Install a current driver for the network
card that supports the NDIS protocol.
Are you using ES441.1 mod
-
ules common with other
ES4xx modules?
Operate the ES441.1 modules at the
beginning of the module chain close to
the host (PC, drive recorder).
Problem
Diagnostic Questions
Possible Solutions