ETAS
Technical Data
BR_XETK-S3.0
-
User Guide
56
7.11.2
ECU Interface Connector CON2
Fig.
7
-
4
ECU Interface Connector (CON2) Location and Pin Assignment
Connector: FCI_10106813-021112LF
Pin
Signal
Direction Comment
1
DAP0
Output
DAP signal
2
/TRST
Output
JTAG signal
3
GND
Power
Signal ground
4
DAP2
Bidir
DAP signal
5
WDGIS
Output
Watchdog disable signal
6
GND
Power
Signal ground
7
VDDP (Sense)
Input
Sense for switched power supply of
ECU (ignition)
8
DAP1
Bidir
DAP signal
9
GND
Power
Signal ground
10
TDI
Output
JTAG signal
11
/ESR0
Bidir
ECU reset signal (open drain) for reset
assertion and supervision
12
GND
Power
Signal ground
13
/PORST
Bidir
ECU Power On Reset signal (open drain)
for Reset assertion and supervision
14
RESERVED1
Output
DNU Mfr test signal
15
DAPE2
Bidir
Extended DAP signal
16
RESERVED2
Output
DNU Mfr test signal
17
DAPE1
Bidir
Extended DAP signal
18
GATE_PORST
Input
Overwrite /PORST status at Power On,
0V = /PORST inactive, 3.3V = active
19
DAPE0
Output
Extended DAP signal
20
GND
Power
Signal Ground
C ON2