ETAS
Technical Data
BR_XETK-S3.0
-
User Guide
48
7.2.2
Measurement Data Memory
7.2.3
Trace Memory
7.3
Configuration
7.4
Environmental Conditions
Item
Characteristics
Location
Typically located within the emulation
memory when using DISTAB17
hooks. Measurement data memory
can be located in internal RAM if the
entire ED RAM is needed for calibra
-
tion.
Item
Characteristics
Trace mirror size
10
3
measurement values (typ.)
Item
Characteristics
Configuration
Project-specific configuration for
- different microcontrollers or
- memory configurations
stored in EEPROM
Update
Logic devices updated using HSP
software
Item
Characteristics
Temperature range (operation)
- 40
°C to +110
°C/ - 40
°F to +230
°F
Temperature range (storage)
0
°C to +50
°C/ - 18
°F to +122
°F
Relative humidity (non-condensing)
0 to 95%
Operating altitude
Max. 5000 m/ 16400 ft
Contamination level
2
Degree of protection
Determined by installation in ECU
Overvoltage category
(AC mains supply)
II