54
www.eta.co.at
Setting the heating time slots
Heating circuit
Setting the heating time slots
Setting the heating time slots
The heating circuit timer can be used to set 3
different time slots for the heating for each day of
the week.
If the unit has a room sensor, a target room
temperature can also be set for each time slot.
Likewise, the reduced room temperature (set-back
temperature) between the heating time slots can
also be adjusted for each day of the week.
"Day" mode
During a set time slot, the heating circuit is in
"Day" mode.
If a room sensor is installed, this regulates the
heating circuit to the set target room temperature
for the time slot.
If there is no room sensor, the flow temperature
of the heating circuit is calculated using the
heating curve.
"Night" mode
Outside the time slots, the heating circuit is in
"Night" mode.
If a room sensor is installed, this regulates the
heating circuit to the stored "set-back tempera-
ture" for the time slot.
If there is no room sensor, the flow temperature of
the heating circuit is calculated using the heating
curve.
Adjusting the timer (with room sensor)
In the overview for the selected heating circuit, tap
the timer. The screen for setting the timer opens.
Overview of current time slots
The current day of the week is selected automati-
cally. The set time slots for the current day of the
week are shown on the screen.
Days of the week
Room temperature only
Set-back temperature
between time slots
3 adjustable time slots
for each day of the week
Target room temperature
room sensor only
Selecting a time slot
Tap the [Time slot 1] line. The time slot setting
screen opens.
The times for “Day” mode can now be altered.
If the unit has a built-in room sensor,
the target room temperature can also be set.
Room
sensor only
Press [Accept] to save the new settings. Use the
same method to adjust the other time slots.