28
www.eta.co.at
Mounting the conveyor pipe
Concluding activities
11.5
Mounting the conveyor pipe
The customer is to mount the conveyor pipe between
transfer coupling and pellet suction system.
Position the welding flanges supplied for
maintenance work in front of ascending and
descending sections.
11.6
Mounting the return hose
The customer mounts the conveyor pipe between
transfer coupling and pellet suction system.
Conveyor pipe
Value
Welded steel pipes
DN 80
Minimum inside diameter
80 mm
Maximum outside diameter
88.9 mm
Maximum length
35 m
Maximum height difference
5 m
Maximum number of bends
7
Minimum radius of bends
400 mm
(EN 10253-1)
Return pipe
Value
Welded steel pipes or PU
hoses
DN 100
(smooth interior
surface)
Temperature range
-40 ° C to 100 ° C
Maximum length
35 m
Maximum height difference
5 m
Minimum radius of bends
300 mm
Earthing
Yes
Segmentation possible
Yes