Information about measurement
Emission measurement
8
Emission measurement
8.1
Information about measurement
8.1.1
Introduction
If possible, perform emissions measurements in
winter only
It is preferable to measure emissions in winter so that
heat consumption to the heating system is ensured
during the emissions measurement.
In spring and fall, the consumers in the heating
system usually need less heat. If emissions are
measured during this time, excess heat cannot be
safely removed from the heating system. As a remedy,
temporarily switch the heating circuits to continuous
"Day" operation. Also temporarily raise the target room
temperature by a few degrees so that the heating
circuits switch on safely. After measuring emissions,
switch back to the original operating mode and room
temperature.
Timely cleaning of the boiler for emissions
measurement
The customer will be notified of the date of emissions
measurement. Thoroughly clean the boiler and flue
duct 3 to 5 days before measuring emissions. Refer to
the documents included with the boiler (maintenance
instructions, operating instructions) for the necessary
steps. Once this is complete, heating can resume as
usual.
If you wait to clean until just before the emissions mea-
surement, large amounts of flue ash will be present in
the flue gas, resulting in false measurement results.
Regular cleaning and maintenance of the boiler is
essential for having low emissions and therefore good
measurement results. You can perform cleaning by
yourself but we recommend contracting a technical
expert for maintenance. Then the heating system will
be well prepared for the emissions measurement.
Required heat-up time and residual oxygen level.
Emissions may be measured only once the boiler has
reached the necessary operating temperature (not
flow temperature). Therefore, once switched on, the
cooled boiler must run for a certain amount of time
(heat-up time) in order to reach the required operating
temperature. These times are indicated in the following
table. Measuring during this heat-up time is thus
prohibited.
Tab. 8-1: required heat-up time
Once the boiler has reached the operating tempera-
ture, the residual oxygen level must be between 4%
and 8%. This is indicated in the boiler's text menu
under:
Tab. 8-2: Current residual oxygen content
If the boiler is at operating temperature and the
residual oxygen level is above 8%, then leak air
is probably getting into the boiler through improperly
sealed boiler doors, the maintenance cover, or
Lambda probe. The cause must be eliminated.
8.1.2
Flue pipe
Provide a short, ascending flue pipe to the
chimney
The flue pipe from the boiler to the chimney must be
short, leakproof and ascending. "Attractive" right-angle
flue offsets with two or more bends are bad in a flue
pipe. The optimum to strive for is the shortest pipe from
the boiler to the chimney with a minimum of direction
changes.
The flue pipe to the chimney must be leakproof. For
unsealed sleeve pipes, use heat-resistant silicone as a
sealant. Otherwise, you can expect smoke to escape
into the boiler room as the boiler heats up. Ensure the
flue pipe always ascends to the chimney
Boiler
Heat-up time (hours)
eHACK
1:30 h
HACK 20-90
1:15 h
HACK 110-130
1:40 h
HACK 200
2:00 h
PE-K 32-90
1:15 h
PE-K 105-140
1:40 h
PE-K 180-220
2:00 h
Log boiler
1:30 h
TWIN pellet burner
1:35 h
PelletsUnit
PelletsCompact 20-32
0:45 h
PelletsCompact 33-50
1:00 h
PelletsCompact 60-105
1:15 h
Boiler
Residual O2
Summary of Contents for 13180LP-T
Page 1: ...2018 05 24 EN 0000000313 V 005 3 43 0 3308 93222 001 Pellet boiler 180 220 kW Operation ...
Page 29: ...ETAtouch controller Getting to know the control system 29 ...
Page 39: ...ETAtouch controller BufferFlex function block 39 ...
Page 47: ...ETAtouch controller Buffer function block 47 ...
Page 51: ...ETAtouch controller Hot water tank function block 51 ...
Page 55: ...ETAtouch controller Fresh water module function block 55 ...
Page 69: ...ETAtouch controller Solar function block 69 ...
Page 87: ......
Page 88: ...www eta co at www eta co at downloads DOWNLOAD ...