Empty the ash bins
13
4
Empty the ash bins
Stop heating
End the boiler's heating mode with the On/Off switch
in the boiler overview window. The boiler
performs an ember burnout and then changes to
[Switched off] mode. Press the [De-ash]
button to
make the boiler perform a final de-ashing.
Remove excess ash from secondary combustion
chamber
Open the combustion chamber door and use the poker
to scrape the excess ash into the combustion
chamber.
The ash in the secondary combustion chamber
may not be steeper than 45°.
To remove this ash, initiate boiler de-ashing by
pressing the [De-ash]
button.
Empty ash bins, check seals
The sight glass can be used to check the fill level
of the ash bins without opening them.
Fig. 4-1: Sight glass
To remove the ash bins, pull the lever on the side
towards the ash bins to release them. Remove the ash
bins from the boiler.
Close the covers in the ash bin lids and fasten them
with the wing nuts.
Fig. 4-2: Covers
Open the fasteners on the lids and empty the ash bins.
Fig. 4-3: Check ash
If there are large pieces of slag in the ash, the
combustion chamber and the tilting grate must be
checked and the de-ashing interval reduced, if
necessary.
Summary of Contents for 13180LP-T
Page 1: ...2018 05 24 EN 0000000313 V 005 3 43 0 3308 93222 001 Pellet boiler 180 220 kW Operation ...
Page 29: ...ETAtouch controller Getting to know the control system 29 ...
Page 39: ...ETAtouch controller BufferFlex function block 39 ...
Page 47: ...ETAtouch controller Buffer function block 47 ...
Page 51: ...ETAtouch controller Hot water tank function block 51 ...
Page 55: ...ETAtouch controller Fresh water module function block 55 ...
Page 69: ...ETAtouch controller Solar function block 69 ...
Page 87: ......
Page 88: ...www eta co at www eta co at downloads DOWNLOAD ...