INTRODUCTION

Thank you for purchasing the ETA-PD8LA AC Power Conditioner & Distribution Unit. The ETA-PD8LA has been designed to meet most 
installation requirements for AC power distribution and equipment power protection. 

The ETA-PD8LA features noise filtering for unwanted Radio Frequency Interference (RFI) that is commonly introduced into AC lines by 
nearby radio transmitters or wireless products. EMI filters are incorporated to reduce noise from Electromagnetic Interference (EMI) 
from such items as electric motors and switching power supplies. The benefit of these filters can be seen on video products or audibly 
by reducing static pops and external signal interference. 

The ETA-PD8LA is unique in that the integrator can select the power cord length that is required for the installation. A removable 12' 
IEC power cord with a retainer bracket is supplied with the unit. A shorter or longer cord can be purchased separately if needed.

Unstable AC Mains voltage is one of the main reasons for equipment failure. The amount of energy that can be injected into the power 
system can be immense with voltages reaching 6kV or amperage peaks of 3000A. These spikes are very fast and usually only last for a 
very short period of time. The ETA-PD8LA’s circuitry is very fast and can suppress unwanted energy within a nanosecond response and 
sustain the suppression up to 2 milliseconds, thus ensuring virtually trouble free protection. The front panel also features AC fault and 
ground status indicators providing quick, visual reassurance the equipment is safe.

The ETA-PD8LA offers power management control, noise filtering, and spike/surge protection, making it the most compact, effective 
power management protection system on the market today.

Summary of Contents for ETA-PD8LA

Page 1: ...ions are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8LA AC Power Conditioner Distribution Unit ETA PD8LA AC Power Condi...

Page 2: ...elephone 800 321 6699 Fax 800 996 3821 ETA PD8LA AC Power Conditioner Distribution Unit TABLE OF CONTENTS Important Safety Instructions 3 Introduction 5 Key Features and Applications 6 Front Panel Des...

Page 3: ...ly with the cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip ov...

Page 4: ...er cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure t...

Page 5: ...ference The ETA PD8LA is unique in that the integrator can select the power cord length that is required for the installation A removable 12 IEC power cord with a retainer bracket is supplied with the...

Page 6: ...cuit Breaker Protection 15A Spike Suppression up to 6000V AC Fault Indicator Ground Status Indicator Removable IEC Power Cord with a Retainer Bracket APPLICATIONS The ETA PD8LA was designed to be flex...

Page 7: ...ssion circuit virtually assures protection from most transient voltage spikes and surges nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to a...

Page 8: ...iner bracket installation 3 AC Mains Power Breaker The 15A rated breaker will open if the combined draw of all AC outlets exceeds 15A Note The breaker is designed to exceed its rating for a short peri...

Page 9: ...ke sure the 15A outlet is properly inspected by a certified electrician prior to connecting the ETA PD8LA Make sure to inspect the equipment that will be connected to the ETA PD8LA to ensure it does n...

Page 10: ...ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8LA AC Power Conditioner Distribution Unit NO...

Page 11: ...ains IEC Power Socket 15A 1800W Circuit Breaker 15A Resettable Technical Data Max AC Mains Current 15A AC Mains Breaker Operating Voltage 102VAC 132VAC Power Consumption 6 Watts Min Spike Clamping Vol...

Page 12: ...forth below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is includ...