ETA-PD8LA 

AC Power Conditioner & Distribution Unit

SPECIFICATIONS

Type 

 Power Conditioner & Suppressor

Load Rating 

15A 

Safety Listings  

ETL (UL 60065 Standard) 

  

Front Panel

Outlets 

  1  Unswitched

Activation Switch 

  Rocker with Security Cover

Indicators 

AC Power On, Outlets Active, AC Fault, Ground

Lights 

1 Pull Out Lamp with Dimmer 

  

Rear Panel

AC Outlets 

  8 Outlets Total, 7 Switched & 1 Unswitched

AC Mains IEC Power Socket 

15A 1800W

Circuit  Breaker 

  15A  Resettable 

  

Technical Data

Max AC Mains Current  

  15A AC Mains Breaker

Operating Voltage 

  102VAC - 132VAC

Power Consumption  

6 Watts

Min. Spike Clamping Voltage 

460 VRMS @ 3,000A

Max. Spike Clamping Voltage 

6kV

Max. Spike Clamping Resp. Time 

1 nanosecond

Spike Clamping Voltage @ 100A 

1250Vp for 20µs

Maximum Surge Current 

6,500A

Energy Rating @ 2ms 

200 Joules

Noise Attenuation RFI 

10dB @ 10kHz / 40dB @ 100kHz / 100dB @ 10MHz

Temperature Range 

5° to 35°C

Humidity Range 

5% to 95% Relative Humidity 

  

Mechanical

Chassis  Finish   

  Black

Mounting 

Rack Mount, 19", 1 RU

Height 

  1.75"  (1RU,  44.5mm)

Width 

  19"  (482.6mm)

Depth 

5" (127mm)

Weight 

5 lbs (2.27kg) 

  

In the Box

Manual

IEC Power Cord 14 Gauge 12ft (4M)

IEC Power Cord Retainer Bracket

Summary of Contents for ETA-PD8LA

Page 1: ...ions are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8LA AC Power Conditioner Distribution Unit ETA PD8LA AC Power Condi...

Page 2: ...elephone 800 321 6699 Fax 800 996 3821 ETA PD8LA AC Power Conditioner Distribution Unit TABLE OF CONTENTS Important Safety Instructions 3 Introduction 5 Key Features and Applications 6 Front Panel Des...

Page 3: ...ly with the cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip ov...

Page 4: ...er cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure t...

Page 5: ...ference The ETA PD8LA is unique in that the integrator can select the power cord length that is required for the installation A removable 12 IEC power cord with a retainer bracket is supplied with the...

Page 6: ...cuit Breaker Protection 15A Spike Suppression up to 6000V AC Fault Indicator Ground Status Indicator Removable IEC Power Cord with a Retainer Bracket APPLICATIONS The ETA PD8LA was designed to be flex...

Page 7: ...ssion circuit virtually assures protection from most transient voltage spikes and surges nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to a...

Page 8: ...iner bracket installation 3 AC Mains Power Breaker The 15A rated breaker will open if the combined draw of all AC outlets exceeds 15A Note The breaker is designed to exceed its rating for a short peri...

Page 9: ...ke sure the 15A outlet is properly inspected by a certified electrician prior to connecting the ETA PD8LA Make sure to inspect the equipment that will be connected to the ETA PD8LA to ensure it does n...

Page 10: ...ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8LA AC Power Conditioner Distribution Unit NO...

Page 11: ...ains IEC Power Socket 15A 1800W Circuit Breaker 15A Resettable Technical Data Max AC Mains Current 15A AC Mains Breaker Operating Voltage 102VAC 132VAC Power Consumption 6 Watts Min Spike Clamping Vol...

Page 12: ...forth below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is includ...

Reviews: