background image

 

– 3 – 

ETAsys.com

Specifications are subject to change without notice.

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800-321-6699 • Fax: 800-996-3821

ETA-PD8LA 

AC Power Conditioner & Distribution Unit

IMPORTANT SAFETY INSTRUCTIONS

1.  Read these instructions.

2.  Keep these instructions.

3.  Heed all warnings.

4.  Follow all instructions.

5.  Do not use this device near water.

6.  Clean only with dry cloth.

7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other device (including amplifiers)  
 

that produce heat. 

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the 
 

other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your  

 

safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they  
 

exit from the device.

11. Only use attachments/accessories specified by the manufacturer.

12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the device. When a cart is used,  
 

use caution when moving the cart/device combination to avoid injury from tip-over.  

13. Unplug this device during lightning storms or when unused for long periods of time. 

14. Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, such as  
 

liquid has been spilled, or objects have fallen into the device, the device has been exposed to rain or moisture, does not operate  

 

normally, or has been dropped. 

15. 

WARNING:

 To reduce the risk of fire or electric shock, this device should not be exposed to rain or moisture and objects filled with  

 

liquids, such as a vase, should not be placed on this device. 

16. To completely disconnect this equipment from the mains, disconnect the power supply cord plug from the receptacle. 

17. The mains plug of the power supply cord shall remain readily operable. 

The lightning flash with arrowhead symbol within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage “ within the 
product’s enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons. 

The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the 
literature accompanying the product.  

Summary of Contents for ETA-PD8LA

Page 1: ...ions are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8LA AC Power Conditioner Distribution Unit ETA PD8LA AC Power Condi...

Page 2: ...elephone 800 321 6699 Fax 800 996 3821 ETA PD8LA AC Power Conditioner Distribution Unit TABLE OF CONTENTS Important Safety Instructions 3 Introduction 5 Key Features and Applications 6 Front Panel Des...

Page 3: ...ly with the cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip ov...

Page 4: ...er cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock Ensure t...

Page 5: ...ference The ETA PD8LA is unique in that the integrator can select the power cord length that is required for the installation A removable 12 IEC power cord with a retainer bracket is supplied with the...

Page 6: ...cuit Breaker Protection 15A Spike Suppression up to 6000V AC Fault Indicator Ground Status Indicator Removable IEC Power Cord with a Retainer Bracket APPLICATIONS The ETA PD8LA was designed to be flex...

Page 7: ...ssion circuit virtually assures protection from most transient voltage spikes and surges nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to a...

Page 8: ...iner bracket installation 3 AC Mains Power Breaker The 15A rated breaker will open if the combined draw of all AC outlets exceeds 15A Note The breaker is designed to exceed its rating for a short peri...

Page 9: ...ke sure the 15A outlet is properly inspected by a certified electrician prior to connecting the ETA PD8LA Make sure to inspect the equipment that will be connected to the ETA PD8LA to ensure it does n...

Page 10: ...ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA PD8LA AC Power Conditioner Distribution Unit NO...

Page 11: ...ains IEC Power Socket 15A 1800W Circuit Breaker 15A Resettable Technical Data Max AC Mains Current 15A AC Mains Breaker Operating Voltage 102VAC 132VAC Power Consumption 6 Watts Min Spike Clamping Vol...

Page 12: ...forth below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is includ...