modules are found to be defective. 
ET  Solar  recommends  the  following  maintenance  items  to  ensure  optimal 
performance of the module. 

 

6.1 Cleaning 

 

Clean  the  glass  surface  of  the  module  as  necessary.  It  is  recommended  to 
clean  the  glass  surface  with  pressured  running  water  compliance with  local 
drinking  standards,  e.g.  low  mineral  content,  near  neutral  PH  value.  The 
maximum water pressure recommended is 0.7 MPa and the water jet is at least 
50cm away from the glass surface. Do not use dishwasher detergent. Do not 
have water staying on the glass surfaces of PV modules for a long time. 

 

If a module power decreases abnormally, and its glass surface is found covered 
by dust, please contact your module installer, retailer or ET solar immediately 
for technical support. 

 

Do not attempt to clean a module if the glass is broken. 

 

Electrical  and  mechanical  connections  should  be  checked  periodically  by 
qualified personnel to verify that they are clean, secure and undamaged.   

 

Problems should only be investigated by qualified personnel.   

 

  Observe  the  maintenance  instructions  for  all  other  components  used  in  the 

system.   

 

  Please refer to”cleaning manual” for specific contents. 

 

6.2 The visual inspection of the modules 

Inspect the modules visually to find if there are appearance defects, especially: 

 

whether the module glass is broken.   

 

If there is burning vestige on the backsheet. 

 

Corrosion along the cells’ bus-bar. The corrosion is caused by the dampness 
infiltrated  into  the  modules  when  the  surface  encapsulation  material  is 
damaged during the installation or transportation. 

 

Check if any obstacles shading the PV modules 

 

6.3 Inspection of the connector and cable 

It is suggested to carry out the following preventive inspection every 6 months.   

 

Check the encapsulation of the connector with the cable 

 

Check the sealing gel of the junction box to ensure it is not cracked or creviced. 

7

 

Disclaimer of liability 

Because  the  use  of  this  manual  and  the  conditions  or  methods  of  installation, 
operation, use and maintenance of photovoltaic products are beyond ET Solar's 
control, ET Solar does not accept responsibility and expressly disclaims liability for 
loss,  damage,  or  expense  arising  out  of  or  in  any  way  connected  with  such 
installation, operation, use or maintenance. No responsibility is assumed by ET Solar 
for any infringement of patents or other rights of third parties, which may result from 

Summary of Contents for ET-M660BH BB Series

Page 1: ...www etsolar hk INSTALLATION MANUAL ET Solar Series Module Installation Safety instructions Maintenance...

Page 2: ...www etsolar hk Version 2021Q1...

Page 3: ...ting the proper mounting structure and hardware 4 4 2 Mounting methods 4 4 2 1 Mounting with bolts 5 4 2 2 Mounting with clamping hardware 5 4 2 3 Installation position and static loads 6 5 Electrical...

Page 4: ...ompliance with this installation instruction may result in property damage and or physical injury ET Solar will not be liable for compensation of any loss or injury caused by this type of non complian...

Page 5: ...85 If modules are to be installed in areas where the temperature may go outside the above range please consult with ET Solar before installation Do not attempt to disassemble the module and do not re...

Page 6: ...ble Only connect modules with the same rated output current in series If modules are connected in series the total voltage is equal to the sum of the individual module voltages The maximum system volt...

Page 7: ...lecting the location Tilt Angle Select a suitable location for installation of the module For optimum performance the module must be facing true south in northern latitudes and true north in southern...

Page 8: ...r with spring washers and flat washers in eight symmetrical locations on the pv module The applied torque value should be big enough to fix the modules steadily Please find detailed mounting informati...

Page 9: ...www etsolar hk 6 4 2 3 Installation position and static loads...

Page 10: ...f PV module array is connected to earth during all PV system installations That will keep optimal performance of PV Power Plants which are located in a hot high humidity climate and high Maximum Syste...

Page 11: ...ng through the hot spot cells in order to prevent module over heated and performance loss Notice bypass diode is not the overcurrent protection device If the diode is suspected to be defective the ins...

Page 12: ...used in the system Please refer to cleaning manual for specific contents 6 2 The visual inspection of the modules Inspect the modules visually to find if there are appearance defects especially wheth...

Page 13: ...xperience and is believed to be reliable but such information including product specification without limitations and suggestions does not constitute a warranty expressed or implied ET Solar reserves...

Page 14: ...www etsolar hk 11 Sheet 2 solar cell type 158 75mm...

Page 15: ...www etsolar hk 12 Sheet 3 solar cell type 156 75mm mono si poly si Sheet 4 solar cell type 182mm For module specifications or datasheets please download from www etsolar hk...

Page 16: ...NG LIMITED Room 01 21 F XINGFA Commercial Building 9th Tobacco Factory Street Mong Kok HongKong Tel 86 510 85382358 Fax 86 510 85382358 Mail support etsolar hk www etsolar hk ET SOLAR INC 4900 Hopyard...

Reviews: