5.2
Communication Setting
Before establishing a network connection between the power supply and the remote
workstation/PC, make sure that the remote workstation/PC and the power supply are on the
same network segment. The default network address of the power supply is 192.168.1.2, the
port is 502, and the default gateway is 255.255. 255.0. Click “File” → “Communication”, and the
power IP address and port are shown in Figure 5-6.
The IP address of the remote workstation /PC should be the different from the IP address of the
power supply. If the remote workstation /PC and power supply are in the LAN, ensure the IP
addresses do not conflict with other equipment on the network.
In addition, the TFT-touch software and the program-controlled GUI software of the power
supply have the same operation method.
Work Station/PC
Power Supply
Figure 5-4 Power supply connected to workstation/PC
Work Station/PC
Power Supply
Network Switch
Printer
Other Device
Figure 5-5 LAN connection of power supply and workstation/PC