GB
6
GB
GAS DETECTOR
Congratulations on your purchase of this high-quality ESYLUX product. To ensure proper operation,
please read these user instructions carefully and keep them for future reference.
1 • SafETY INSTRuCTIoNS
CAUTION: Work on the 230 V power system must be carried out by authorised personnel only with due regard
to the applicable installation regulations. Switch off the power supply before installing the system.
Use this product only as intended (as described in the user instructions). Changes or modifications
to the product or painting it will result in loss of warranty. You should check the device for damage
immediately after unpacking it. If there is any damage, you should not install the device under any
circumstances. If you suspect that safe operation of the device cannot be guaranteed, you should turn
the device off immediately and make sure that it cannot be operated unintentionally.
2 • DESCRIpTIoN
The PROTECTOR GD 230 V ∼ is a gas detector with an electronic
sensor for natural
gas (CNG, methane) and liquefied/bottled gas (LPG, propane/butane)
designed for use in residential buildings.
If gas escapes, it will trigger a widely audible alarm signal (approx. 85 dB) long before a flammable
mixture of air and gas forms.
It is also possible to relay the alarm signal via a 9 V output (e.g. to the PROTECTOR 9 V smoke detector).
For optimum protection of your home, install the PROTECTOR GD 230 V ∼ in all rooms
in which a gas appliance is used (e.g. kitchen with gas oven, living rooms with gas
heaters, furnace room with gas boiler, gas meter closet).
3 • INSTallaTIoN / aSSEMBlY / CoNNECTIoN
The PROTECTOR GD 230 V ∼ is designed for wall mounting. The mounting height
depends on the type of the gas:
•
Natural gas (CNG, methane)
is lighter than air and collects beneath the ceiling.
The PROTECTOR GD 230 V ∼ needs to be mounted on the wall approx. 30 cm
below ceiling level.
•
Liquefied/bottled gas (LPG, propane/butane)
is heavier than air and collects at floor level.
The PROTECTOR GD 230 V ∼ needs to be mounted on the wall approx. 30 cm above
floor level.
NOTE:
• Do not install in rooms with high ambient humidity or steam (e.g. in
bathrooms or directly above an oven)
• Do not install in the immediate vicinity of gas appliances (e.g. directly
above an oven or heating system)
• Do not install in very dusty or dirty areas
• Install the gas detector mounting plate on the wall
(fig. 1)
or, if more wiring space is
required, on a recessed box
(fig. 1e)
.
• Mount the PROTECTOR GD 230 V ∼ on the mounting plate and push until it clicks
into place
(fig. 2)
.