background image

230 VAC

  12  VDC

230 VAC

  12  VDC

  Belonging  to

To protect your family

RGX100 - 

V. 14

Household gas  detector

Important: Assembly / maintenance of the appliance must be carried out by qualified personnel and in
accordance with applicable laws and regulations.
The manufacturer assumes no responsibility for the use of products that have to comply with particular
environmental and / or installation standards.

Important note
Before connecting the equipment, it is recommended that you read the instruction manual carefully and
keep it for future reference. It is also recommended to perform the electrical connections correctly as
per enclosed drawings, observing the instructions and the Standards.
N.B. Refer to the documentation in all cases where the symbol is on the side

Channel:  Beinat  gas  solutions

Electric connections also available on

CONFORMITY

Installation and user
guide

EN 50194
EN 50270

CEI 216-3

EN 61010-1

Installation  EN 60079-29-2

   Reports issued by     TUV Italia

The elegance and the prestige, that have always made BEINAT S.r.l stand out from its competitors,
together  with  the  concept  of  home  fitness  comes  the  household  gas  detector  RGX100  detects
through the catalytic sensor , the presence of explosive gas such as: Methane, LPG.

Gas detection

The detector is tested and calibrated to  10% of L.E.L.
The power supply unit allows driving of a manual reset solenoid valve with a 12Vdc coil, without any buffer
battery. If the voltage absorption is too high, you can later integrate a suitable backup battery. The
battery is recharged automatically.
Through the built-in relay,  the RGX100 can activate: solenoid valves, sirens, and any other device
alarm.
A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.
 through an internal jumper it is possible to select the relay impulse functioning, to connect manual
reset solenoid valves, or the continuous functioning, to activate class “A” solenoid valves and sirens.
The relay, free of voltage, allows installation of multiple detectors on a single solenoid valve ensuring
control of multiple dangerous environments.
  The  detector  is  complete  with  a  special  circuit  that controls the  catalytic sensor’s efficiency
level
, and signals any possible fault
These technical features make the detector ideal for the safety of civil environments according to
EUROPEAN STANDARD.

Summary of Contents for RGX100

Page 1: ...ith the concept of home fitness comes the household gas detector RGX100 detects through the catalytic sensor the presence of explosive gas such as Methane LPG Gas detection The detector is tested and calibrated to 10 of L E L The power supply unit allows driving of a manual reset solenoid valve with a 12Vdc coil without any buffer battery If the voltage absorption is too high you can later integra...

Page 2: ...a specialized technician The disposal of the detector 5 years after installation It must be carried out by qualified technician Mains power 230VAC 50 60 Hz 10 Battery power 12 VDC 1 2 Ah 10 Current consumption 3 1 W 230V Range of relay contact switching 10A 250V resistive 5A 30Vdc resistive Battery charger Max Built in for a 1 2Ah 12VDC battery Insulation Class II Explosive gas sensor Catalytic Ex...

Page 3: ...ds and then will reopen them This is needed to prevent damaging some types of manual reset solenoid valve coils This features is suitable only when a 12 Vdc electrovalve is connected By opening the two poles the relay will be set to continuous functioning 6 Relay This relay changes its position when the detector trigger the main alarm 7 Catalytic sensor for Methane or LPG explosive gas detection 8...

Page 4: ...e free Power supply 230 240 VAC Electrical connections WARNING Before connecting to the mains power ensure the voltage is correct Carefully follow the instructions and the connections according to Regulations in force An automatic disconnetting switch appropriately identified as the detector sectioning device must be incorporated in the electrical system suitably located and easily accessible N C ...

Page 5: ...tery 12VDC 1 2Ah MAX N B The 12VDC voltage can be derived from another source Normaly open solenoid valve 12VDC N C C NO 1 2 3 4 5 6 7 Solenoid valve NA 12 VDC Connection with a normally closed solenoid valve 12 VDC N C C NO N Ph 1 2 3 4 5 6 7 230 240 VAC Solenoid valve NA 12 VDC ATTENTION Relay is voltage free The power supply is 230 240 VAC with a buffer battery 12VDC 1 2Ah MAX N C C NO 1 2 3 4 ...

Page 6: ...r should not be installed in environments where the temperature drops below 10 C or rises above 40 C The detector is equipped to detect different types of gases and according to these its must to be positioned at different heights These heights are 30 cm from the lowest point of the floor in order to detect heavy gases LPG etc 30 cm from the highest point of the ceiling in order to detect light ga...

Page 7: ...oes into alarm and closes the connected equipment Check that connections are correct and that the jumper which leads to the common voltage of the relay has been carried out all the relays are voltage free Check the scheme of connection If RGX100 is connected to a Solenoid valves 12 VDC and does not work To RGX100 you can not connect directly solenoid valves sirens in 12 VDC It must always to use t...

Page 8: ...excluded from the warranty BEINAT S r l is not liable for possible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collec...

Reviews: