CHAPTER 6
SERIAL APPLICATIONS
USING THE USB PROGRAMMING PORT
Any terminal emulation program can be used for this configuration of the ESTeem 210 through the USB port. Most Windows
users will probably use either Hyper Terminal or the Terminal Emulation in the ESTeem Utility program.
Programming Using the USB Port
1.
2.
3.
4.
5.
6.
7.
8.
When configuring the Model 210 for the first time you can use the ESTeem Configuration Menu to setup the basic operating
parameters such as assigning the IP Address, IP Net Mask, and Gateway IP Address.
Connect the USB cable between the USB connector on the Model 210 to an open USB port on the computer.
Plug the Model AA174 power supply into a wall socket and connect an Ethernet patch cable from the Model 210 Ethernet port
to the J1 (Data&PWR) port on the power supply. The Power LED on the front of the ESTeem should be illuminated.
If your computer is configured properly, you will see the ESTeem Model 210 booting sequence on your Terminal Emulation
program. Once the ESTeem boot sequence is complete (approximately 45 seconds) you will receive this message:
“Please press Enter to active this console.”
If you don’t see this message press the Reset button on the front panel of the Model 210 and/or check the programming of
your RS-232 port.
Press the Enter key and you will be at the Configuration Menu 210 login prompt. See Figure 1.
To enter the Model 210 Main Menu you will need to log into the system with a login name and password.
If this is not the first time configuration of the Model 210, see your network systems administrator for the password.
At the 210 login prompt type
admin
for the login name and press the
Enter key (<Enter>).
The login name is defined at the
factory and is not changeable by the user.
Note that all characters are lower case.
If this is the first time the Model 210 has been programmed or the Password was not changed from the factory default values, the
factory default password is also
admin
. Enter
admin
for the password and press the Enter key (<Enter>). The ESTeem
Configuration Welcome Screen (Figure 2) will now be displayed.
Note that all characters are lower case.
Figure 1: RS-232 Port Log-in Screen
Revised: 5 Dec 12
6-1
EST P/N AA107-210CM